IV. NPDES Applications for Stormwater Discharges from Municipal Separate Storm Sewer Systems (MS4)
V. Applications for NPDES Wavier Stormwater Discharges from Municipal Separate Storm Sewer Systems (MS4)
VI. NPDES Individual Permit Applications for Discharges of Stormwater Associated with Construction Activities
Southeast Region: Water Management Program Manager, 2 East Main Street, Norristown, PA 19401.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI010907023 Marc Stolt
2519 Camp Rock Hill Road
Quakertown, PA 18901Bucks Milford Township Unami Creek
HQ-TSFPAI010907024 Richard D. Zaveta, Jr.
4030 Skyron Drive
Doylestown, PA 18902Bucks Buckingham Township Pauncaussing Creek
HQ-CWFPAI010907025 Bensalem Redevelopment, LP
2310 Terwood Drive
Huntingdon Valley, PA 19006Bucks Bensalem Township Delaware River
WWF-MFPAI010908001 Charles Reese
765 Nemeth Road
Coopersburg, PA 18006Bucks Springfield Township Cooks Creek
EVPAI010908002 99 Warrington, LLC
29 Somers Road
Hampden, MA 10136Bucks Warrington Township
Little Neshaminy Creek
WWF-MFPAI011508005 Morphotek, Inc.
210 Welsh Pool Road
Exton, PA 19341Chester Uwchlan Township Pine Creek
HQPAI011508006 Saratoga Management
1120 Clover Lane
Glen Mills, PA 19342Chester West Bradford Township UNT Broad Run
EVPAI011508007 George Thornton
P. O. Box 248
Uwchland, PA 19480Chester Wallace Township East Branch Brandywine Creek
HQPAI011508008 Immaculata University
1145 King Road
Immaculata, PA 19345Chester East Whiteland Township Ridley Creek
HQPAI011508009 Pine Hill Associates, Inc.
P. O. Box 608
Regent Center
Lionville, PA 19353Chester East Brandywine Township UNT East Branch Brandywine Creek
HQ-TSF-MFPAI014607009 Ambler Square Associates
1574 Easton Road
Warrington, PA 18976Montgomery Ambler Wissahickon Creek
TSFPAI014607010 Valley Forge National Park
1400 North Outer Line Drive
King of Prussia, PA 19406Montgomery Upper Merion Township Valley Creek
CWF-EVPAI015108001 H.E.R.B. CNC
c/o OKKS Development Company
1570 Cecil B. Moore Avenue
Philadelphia, PA 19021Philadelphia City of Philadelphia PWD Wastewater Treatment Plant--Combined
Sewer SystemNortheast Region: Watershed Management Program Manager, 2 Public Square, Wilkes-Barre, PA 18711-0790.
Monroe County Conservation District: 8050 Running Valley Road, Stroudsburg, PA 18360, (570) 629-3060.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI024508002 Pocono Manor Investors, LP
P. O. Box 38
Pocono Manor, PA 18349Monroe Pocono Township Scot Run
HQ-CWFPAS10S020R Keystone Hollow Corporation
P. O. Box 1158
Marshalls Creek, PA 18335Monroe Middle Smithfield Township Marshall Creek
HQ-CWF
Bushkill Creek
HQ-TSF
Delaware River
HQ-CWFNorthampton County Conservation District: Greystone Building, Gracedale Complex, Nazareth, PA 18064-9211, (610) 746-1971.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI024808004 Easton Area School Distict
1801 Bushkill Drive
Easton, PA 18040Northampton Forks Township Bushkill Creek
HQ-CWFPike County Conservation District: HC 6, Box 6770, Hawley, PA 18428, (570) 226-8220.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI025208001 Masthope Mountain Community Property Owners Council
HC 1A
Box 353
Lackawaxen, PA 18435Pike Lackawaxen Township Tributary to Delaware River
HQ-CWFCarbon County Conservation District: 5664 Interchange Road, Lehighton, PA 18235-5114, (610) 377-4894.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI021308001 Tuthill Corporation
Blue Mountain Ski Area
P. O. Box 216
Palmerton, PA 18071Carbon Lower Towamensing Township Aquashicola Creek
HQ-CWF, MFSouthcentral Region: Water Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI030607011 Love's Travel
Stops & Country Stores
P. O. Box 26210
Oklahoma City, OK 73126Berks Upper Bern Township Wolf Creek
CWFNorthwest Region: Watershed Management Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.
Butler County Conservation District: 122 McCune Drive, Butler, PA 16001-6501, (724) 284-5270.
NPDES
Permit No.Applicant Name &
AddressCounty Municipality Receiving
Water/UsePAI061003003R The Village at Sarver's Mill Sarver Square Associates, Inc.
P. O. Box 42
Murrysville, PA 15668Butler Buffalo Township Little Buffalo Creek
HQ-TSF
Sarver Run
HQ-TSF
VII. List of NOIs for NPDES and/or Other General Permit Types
PAG-12 Concentrated Animal Feeding Operations (CAFOs) PAG-13 Stormwater Discharges from Municipal Separate Storm Sewer Systems (MS4)
PUBLIC WATER SUPPLY (PWS) PERMIT Under the Pennsylvania Safe Drinking Water Act (35 P. S. §§ 721.1--721.17), the following parties have applied for a PWS permit to construct or substantially modify a public water system.
Persons wishing to comment on a permit application are invited to submit a statement to the office listed before the application within 30 days of this public notice. Comments received within the 30-day comment period will be considered in the formulation of the final determinations regarding the application. Comments should include the name, address and telephone number of the writer and a concise statement to inform the Department of Environmental Protection (Department) of the exact basis of a comment and the relevant facts upon which it is based. A public hearing may be held after consideration of comments received during the 30-day public comment period.
Following the comment period, the Department will make a final determination regarding the proposed permit. Notice of this final determination will be published in the Pennsylvania Bulletin at which time this determination may be appealed to the Environmental Hearing Board.
The permit application and any related documents are on file at the office listed before the application and are available for public review. Arrangements for inspection and copying information should be made with the office listed before the application.
Persons with a disability who require an auxiliary aid, service or other accommodations to participate during the 30-day public comment period should contact the office listed before the application. TDD users should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.
SAFE DRINKING WATER
Applications Received under the Pennsylvania Safe Drinking Water Act
Northeast Region: Water Supply Management Program, 2 Public Square, Wilkes-Barre, PA 18711-0790.
Application No. 6608501, Public Water Supply.
Applicant Terrace View Park Water Association Falls Township
Wyoming CountyResponsible Official Mike Rincavage
Terrace View Park Water Association
9 Hemlock Drive
Tunkhannock, PAType of Facility Public Water System Consulting Engineer Milnes Engineering, Inc.
12 Frear Hill Road
Tunkhannock, PAApplication Received Date January 22, 2008 Description of Action The permitting of an existing water system that includes a well, hypochlorination and a storage/contact tank. Southcentral Region: Water Supply Management Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110.
Permit No. 5008501, Public Water Supply.
Applicant Creekview Farms Mobile Home Park Municipality Carroll Township County Perry Responsible Official Creekview Farms Mobile Home Park, Owner
280 Airy View Road
Shermans Dale, PA 17090Type of Facility Public Water Supply Consulting Engineer Charles A. Kehew II, P. E.
James R. Holley & Assoc., Inc.
18 South George Street
York, PA 17401
Application Received: January 31, 2008 Description of Action New Well No. 8
WATER ALLOCATIONS
Applications received under the Act of June 24, 1939 (P. L. 842, No. 365) (35 P. S. § 631--641) relating to the Acquisition of Rights to Divert Waters of the Commonwealth
Northwest Region: Water Supply Management Program Manager, 230 Chestnut Street, Meadville, PA 16335-3481.
WA 16-1006, Water Allocations. Hawthorn Area Water Authority, P. O. Box 241 Hawthorn, PA 16230-0241. Hawthorn Borough and Redbank Township, Clarion County and Redbank Township, Armstrong County. The permittee has requested an allocation of 30,000 gpd from the Redbank Valley Municipal Authority on an emergency basis and will also be expanding their service area to provide service to 120 connections in the Oakridge area.
LAND RECYCLING AND ENVIRONMENTAL REMEDIATION
UNDER ACT 2, 1995
PREAMBLE 1
Acknowledgment of Notices of Intent to Remediate Submitted under the Land Recycling and Environmental Remediation Standards Act (35 P. S. §§ 6026.101--6026.908).
Sections 302--305 of the Land Recycling and Environmental Remediation Standards Act (act) require the Department of Environmental Protection (Department) to publish in the Pennsylvania Bulletin an acknowledgment noting receipt of Notices of Intent to Remediate. An acknowledgment of the receipt of a Notice of Intent to Remediate is used to identify a site where a person proposes to, or has been required to, respond to a release of a regulated substance at a site. Persons intending to use the Background Standard, Statewide Health Standard, the Site-Specific Standard or who intend to remediate a site as a special industrial area must file a Notice of Intent to Remediate with the Department. A Notice of Intent to Remediate filed with the Department provides a brief description of the location of the site, a list of known or suspected contaminants at the site, the proposed remediation measures for the site and a description of the intended future use of the site. A person who demonstrates attainment of one, a combination of the cleanup standards or who receives approval of a special industrial area remediation identified under the act will be relieved of further liability for the remediation of the site for any contamination identified in reports submitted to and approved by the Department. Furthermore, the person shall not be subject to citizen suits or other contribution actions brought by responsible persons not participating in the remediation.
Under sections 304(n)(1)(ii) and 305(c)(2) of the act, there is a 30-day public and municipal comment period for sites proposed for remediation using a Site-Specific Standard, in whole or in part, and for sites remediated as a special industrial area. This period begins when a summary of the Notice of Intent to Remediate is published in a newspaper of general circulation in the area of the site. For the sites identified, proposed for remediation to a Site-Specific Standard or as a special industrial area, the municipality within which the site is located may request to be involved in the development of the remediation and reuse plans for the site if the request is made within 30 days of the date specified. During this comment period, the municipality may request that the person identified as the remediator of the site develop and implement a public involvement plan. Requests to be involved and comments should be directed to the remediator of the site.
For further information concerning the content of a Notice of Intent to Remediate, contact the environmental cleanup program manager in the Department regional office before which the notice appears. If information concerning this acknowledgment is required in an alternative form, contact the community relations coordinator at the appropriate regional office. TDD users may telephone the Department through the AT&T Relay Service at (800) 654-5984.
The Department has received the following Notices of Intent to Remediate:
Southcentral Region: Environmental Cleanup Program Manager, 909 Elmerton Avenue, Harrisburg, PA 17110.
New Cumberland Army Depot/IRP Site 63, Fairview Township, York County. Defense Distribution Depot, Susquehanna, PA, 2001 Mission Drive, New Cumberland, PA 17070 submitted a Notice of Intent to Remediate site groundwater contaminated with chlorinated solvents. This military site will be remediated to the Site-Specific Standard.
Southwest Region: Environmental Cleanup Program Manager, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.
Interstate Transformer Inc., (Former), and National Plumbing Fixture Facility, Ellwood City Borough, Beaver and Lawrence Counties. J. Scott Whipkey, R.A.R. Engineering Group, Inc., 1135 Butler Avenue, New Castle, PA 16101 on behalf of Jim Elliott and Mike Ritzert, R.W. Elliott and Sons, Inc., R. D. 1, Box 242, Ellwood City, PA 16117 and Mark McClymonds, RWE Realty, LLC, Currie Road, P. O. Box 269, Portersville, PA 16051 has submitted a Notice of Intent to Remediate. Previous investigations conducted at the site indicate that site soils have been impacted with PCB's. Proposed remediation measures are to eliminate current and future exposure pathways by prohibiting excavations in the area of impacted soils and by prohibiting the use of groundwater as a potable water source. The intended future use is nonresidential.
Baylor's Mobil Station (Former), Monroeville Borough, Allegheny County. Michael Smith, CP Environmental Group, Inc., 1092 Fifth Avenue, New Kensington, PA 15068 on behalf of James Bishop, P. O. Box 47, Turtle Creek, PA 15145 has submitted a Notice of Intent to Remediate. Groundwater is impacted with gasoline at concentrations above Statewide Health Standards. The source of the impacts is likely underground storage tank systems operated at the site prior to 1972. Benzene, ethylbenzene, xylenes and naphthalene concentrations have been detected at concentrations above Statewide Health Standards. Future property use will likely continue to be nonresidential.
Allegheny Power, Connellsville West Side Facility, Connellsville Borough, Fayette County. Steven Gerritsen, SE Technologies, LLC, 98 Vanadium Road, Bridgeville, PA 15017 on behalf of David Flitman, Allegheny Power, 800 Cabin Hill Drive, Greensburg, PA 15601 has submitted a Notice of Intent to Remediate. The subject property is used as a service center to support the electrical utility industry. Environmental investigations have identified one area of concern on the property. The primary environmental issue is related to a historical release of organic and inorganic constituents related to historic facility operations. Remedial measures are ongoing in the form of a groundwater recovery and containment system. Future land use is to be industrial. A Statewide Health Standard is proposed.
HAZARDOUS WASTE TREATMENT, STORAGE AND DISPOSAL FACILITIES
Applications received under the Solid Waste Management Act of July 7, 1980 (P. L. 380, No. 97) (35 P. S. §§ 6018.101--6018.1003) and Regulations to Operate a Hazardous Waste Treatment, Storage or Disposal Facility.
Southeast Region: Regional Solid Waste Manager, 2 East Main Street, Norristown, PA 19401.
Permit Application No. PAD085690592. Republic Environmental Systems (Pennsylvania), LLC, 2869 Sandstone Drive, Hatfield, PA 19440, Hatfield Township, Montgomery County. This application is for the conversion of Republic Environmental Systems (Pennsylvania), Inc., from a corporation to a limited liability company. The application was received in the SERO on January 15, 2008.
OPERATE WASTE PROCESSING OR DISPOSAL AREA OR SITE
Application Received under the Solid Waste Management Act (35 P. S. §§ 6018.101--6018.1003), the Municipal Waste Planning, Recycling and Waste Reduction Act (53 P. S. §§ 4000.101--4000.1904) and Regulations to Operate Solid Waste Processing or Disposal Area or Site.
Southeast Region: Regional Solid Waste Manager, 2 East Main Street, Norristown, PA 19401.
Permit Application No. 100708. Jones & Losito, Inc., 3200 Reedville Road, Oxford, PA 19363-1711, Lower Oxford Township, Chester County. This application is to reissue the municipal waste permit from Cloud Disposal, Inc. to Jones & Losito, Inc. as the new operator. The application was received by Southeast Regional Office on January 30, 2008.
Application review timeline was negotiated under the Solid Waste Management Act (35 P. S. §§ 6018.101--6018.1003), the Municipal Waste Planning, Recycling and Waste Reduction Act (53 P. S. §§ 4000.101--4000.1904) and Regulations to Operate Solid Waste Processing or Disposal Area or Site.
Northcentral Region: Regional Solid Waste Manager, 208 West Third Street, Williamsport, PA 17701.
Permit Application No. 100955. Clinton County Solid Waste Authority, 264 Landfill Lane, P. O. Box 209, McElhattan, PA 17748-0209, located in Wayne Township, Clinton County. The Local Municipal Involvement Process meeting for the major permit modification for expansion of the Wayne Township Landfill was held on February 6, 2008. During this meeting an alternate review timeline of 660 days was negotiated between Clinton County, Wayne Township, the applicant, and the Department of Environmental Protection (Department).
Comments concerning the application should be directed to David Garg, P. E., Facilities Manager, Williamsport Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Persons interested in obtaining more information about the permit application may contact the Williamsport Regional Office, (570) 327-3740. TDD users may contact the Department through the Pennsylvania Relay Service (800) 654-5984.
AIR QUALITY
PLAN APPROVAL AND OPERATING PERMIT APPLICATIONS
NEW SOURCES AND MODIFICATIONS The Department of Environmental Protection (Department) has developed an ''integrated'' plan approval, State operating permit and Title V operating permit program. This integrated approach is designed to make the permitting process more efficient for the Department, the regulated community and the public. This approach allows the owner or operator of a facility to complete and submit all the permitting documents relevant to its application one time, affords an opportunity for public input and provides for sequential issuance of the necessary permits.
The Department has received applications for plan approvals and/or operating permits from the following facilities.
Copies of the applications, subsequently prepared draft permits, review summaries and other support materials are available for review in the regional office identified in this notice. Persons interested in reviewing the application files should contact the appropriate regional office to schedule an appointment.
Persons wishing to receive a copy of a proposed plan approval or operating permit must indicate their interest to the Department regional office within 30 days of the date of this notice and must file protests or comments on a proposed plan approval or operating permit within 30 days of the Department providing a copy of the proposed document to that person or within 30 days of its publication in the Pennsylvania Bulletin, whichever comes first. Interested persons may also request that a hearing be held concerning the proposed plan approval and operating permit. Comments or protests filed with the Department regional offices must include a concise statement of the objections to the issuance of the Plan approval or operating permit and relevant facts which serve as the basis for the objections. If the Department schedules a hearing, a notice will be published in the Pennsylvania Bulletin at least 30 days prior the date of the hearing.
Persons with a disability who wish to comment and require an auxiliary aid, service or other accommodation to participate should contact the regional office identified before the application. TDD users should contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984. Final plan approvals and operating permits will contain terms and conditions to ensure that the source is constructed and operating in compliance with applicable requirements in 25 Pa. Code Chapters 121--143, the Federal Clean Air Act (act) and regulations adopted under the act.
PLAN APPROVALS
Plan Approval Applications Received under the Air Pollution Control Act (35 P. S. §§ 4001--4015) and 25 Pa. Code Chapter 127, Subchapter B that may have special public interest. These applications are in review and no decision on disposition has been reached.
Northcentral Region: Air Quality Program, 208 West Third Street, Williamsport, PA 17701, David Aldenderfer, Program Manager, (570) 327-3637.
08-00002D: E.I. duPont de Nemours & Co., Inc. (Patterson Boulevard, Towanda, PA 18848) for installation of an air cleaning device (a regenerative thermal oxidizer) on two existing film coaters (No. 3 Coater and No. 9 Coater) and a coating solutions preparation area (Building 62 Solutions Preparation Area) in North Towanda Township, Bradford County.
Intent to Issue Plan Approvals and Intent to Issue or Amend Operating Permits under the Air Pollution Control Act (35 P. S. §§ 4001--4015) and 25 Pa. Code Chapter 127, Subchapter B. These actions may include the administrative amendments of an associated operating permit.
Northeast Region: Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18711-0790, Neal Elko, New Source Review Chief, (570) 826-2531.
13-318-009: Haulmark Industries, Inc. (6 Banks Avenue, McAdoo Industrial Park, McAdoo, PA 18237) for installation of a paint spray booth with filters at their facility in Banks Township, Carbon County. The PM emissions from the booth shall not exceed 0.02 grains/dscf. The company shall comply with 25 Pa. Code § 123.31 for malodorous emissions. The company will operate the facility and maintain the system in accordance with the good engineering practices to assure proper operation of the system. The Plan Approval and Operating permit will contain additional recordkeeping and operating restrictions designed to keep the facility operating within all applicable air quality requirements.
39-399-063: Diageo (7880 Penn Drive, Breinigsville, PA 18031) for the reactivation of beer manufacturing operations including the installation of a new keg filling line and a specialty malt handling line at their facility located in Upper Macungie Township, Lehigh County. The PM emissions from the baghouses shall not exceed 0.02 grains/dscf. The company shall comply with 25 Pa. Code § 123.31 for malodorous emissions. The company shall comply with 25 Pa. Code § 123.41 for visible emissions. The company will operate the facility and maintain the system in accordance with the good engineering practices to assure proper operation of the system. The plan approval and subsequent Title V permit amendment will include emission limits along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations.
Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110, Ronald Davis, New Source Review Chief, (717) 705-4702.
28-05004D: Grove US, LLC (1565 Buchanan Trail East, Shady Grove, PA 17256) for installation of a paint spray booth at their Shady Grove plant in Antrim Township, Franklin County. This is a replacement of an existing booth and VOC emissions from surface coating will not be affected by the new booth's installation. The plan approval and subsequent Title V permit amendment will include emission limits along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations.
36-05123B: Corixa Corporation--d/b/a GlaxoSmith- Kline Biologicals (325 North Bridge Street, Marietta, PA 17547-0304) for change in operation hours and emission limits of an existing emergency engine at the biological manufacturing facility in East Donegal Township, Lancaster County. This will increase the facility NOx emissions by 2.21 tpy. This plan approval will include monitoring, recordkeeping and reporting requirements designed to keep the sources operating within all applicable air quality requirements.
Northcentral Region: Air Quality Program, 208 West Third Street, Williamsport, PA 17701, David Aldenderfer, Program Manager, (570) 327-3637.
49-00033D: Watsontown Brick Company (P. O. Box 68, Route 405, Watsontown, PA 17777-0068) has submitted an application (No. 49-00033D) to the Department of Environmental Protection (Department) for plan approval for the construction and operation of a 5.5 tons per hour brick making operation which includes the following sources: a 31 mmBtu/hr natural gas fired tunnel kiln, the air contaminant emissions controlled by a dry sorbent injection system and two fabric collectors operating in parallel, a 3 mmBtu/hr natural gas fired brick preheater, a 12 mmBtu/hr waste heat/natural gas fired brick dryer, a grinding and brick making operation, the air contaminant emissions controlled by a cartridge collector, a 500 kilowatt diesel fired emergency generator, and several small natural gas combustion sources. The new brick making operation will be designated as Plant No. 3 at their brick making facility located in Delaware Township, Northumberland County. The respective facility is a major facility for which a Title V operating permit 49-00033 has been issued.
The Department's review of the information submitted by Watsontown Brick Company indicates that the proposed plant No. 3 will meet all applicable air quality regulatory requirements pertaining to air contamination sources and the emission of air contaminants, including the fugitive PM emission limitation of 25 Pa. Code § 123.1 and the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12. The proposed grinding and brick making operations will also meet the requirements of Subpart OOO of the New Source Performance Standards, 40 CFR Part 60, 60.670--60.676. Additionally, the proposed diesel generator will meet the requirements of Subpart IIII of the New Source Performance Standards, 40 CFR Part 60, 60.4200--60.4219. Based on these findings, the Department intends to approve the application and issue a plan approval for the construction and operation of all the sources and air cleaning devices for plant No. 3. Additionally, if the Department determines that the sources are operating in compliance with all plan approval conditions, the conditions established in the plan approval will be incorporated into Title V operating permit 49-00033 by means of an administrative amendment under 25 Pa. Code § 127.450.
The following is a summary of the conditions that the Department proposes to place in the plan approval to ensure compliance with all applicable regulatory requirements:
1. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, Source ID P301 is a 5.5 tons per hour natural gas fired Lingl tunnel kiln rated at 31 mmBtu/hr. The air contaminant emissions from Source ID P301 shall be controlled by an ENCERTEC, Inc. model C-5138-DIFF-07, sorbent (lime and sodium bicarbonate) injection system (ID C301A) in series with two C. P. E. Filters, Inc. 6,500 CFM fabric collectors (IDs C301B and C301C) operating in parallel to control the PM emissions from Source ID P301.
2. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, Source ID P301 shall be equipped with 28 Hauck model BIC 80 high velocity natural gas fired burners (each rated at 400,000 Btu/hr) and 72 Lingl model LWGB-15 nozzle mix burners (each rated at 275,000 Btu/hr).
3. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, Source ID P301 shall only be fired on natural gas.
4. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the permittee shall only process Watsontown clay/shale in Source ID P301.
5. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, Source ID P301 shall not emit air contaminants in excess of the following rates:
Particulate Matter (PM) 0.68 lbs/hr 2.97 tons in any 12-consecutive month period VOCs 0.14 lbs/hr 0.61 tons in any 12-consecutive month period Hydrogen Fluoride (HF) 0.46 lbs/hr 2.03 tons in any 12-consecutive month period Hydrogen Chloride (HCl) 0.09 lbs/hr 0.37 tons in any 12-consecutive month period Total HAPs 0.57 lbs/hr 2.62 tons in any 12-consecutive month period SOx 1.62 lbs/hr 7.10 tons in any 12-consecutive month period NOx 1.13 lbs/hr 4.94 tons in any 12-consecutive month period CO 6.71 lbs/hr 29.4 tons in any 12-consecutive month period 6. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the injection rate for the ENCERTEC, Inc. model C-5138-DIFF-07 sorbent (ID C301A) shall be at least 40 lbs/hr of lime and 10 lbs/hr of sodium bicarbonate.
7. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, control device ID C301A shall be equipped with instrumentation which continuously monitors the sorbent injection rate in lbs/hr. Additionally, the permittee shall record this sorbent injection rate, in lbs/hr, at least once per day. These records shall be retained for a minimum of 5 years and shall be provided to the Department upon request.
8. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the PM emissions from the exhausts of each C. P. E. Filters, Inc. fabric collectors (IDs C301B and C301C) shall not exceed 0.005 grains per dry standard cubic foot.
9. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the air compressors which supplies compressed air to the fabric collectors associated with Source ID P301 shall be equipped with an air dryer and oil trap.
10. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the permittee shall keep on hand a sufficient quantity of spare fabric filters for the fabric collectors associated with Source ID P301 in order to be able to immediately replace any filter requiring replacement.
11. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, control device IDs C301B and C301C shall be equipped with instrumentation which continuously monitors the pressure drop across the collectors. Additionally, the permittee shall record the pressure drop across IDs C301B and C301C at least once per day. These records shall be retained for a minimum of 5 years and shall be provided to the Department upon request.
12. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the ENCERTEC, Inc. model C-5138-DIFF-07 sorbent injection system (ID C301A) associated with Source ID P301 shall achieve a minimum removal efficiency of 95% for Hydrogen Fluoride (HF) and 95% for Hydrogen Chloride (HCl).
13. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, none of the material collected by control device IDs C301B and C301C shall be recycled back into the brick making process.
14. Within 180 days of initial operation of Source ID P301 the permittee shall perform hydrogen fluoride (HF), hydrogen chloride (HCl) and SOx testing at the inlet of the dry lime injection system and the outlet of the dry lime injection system to determine the removal efficiency for HF, HCl and SOx. In addition, the permittee shall conduct PM, NOx and CO stack testing at the outlet of the lime injection system's fabric collectors to determine the mass emission rate (pounds per hour) of the respective air contaminants. The testing shall be performed while the kiln is operating at maximum production rate. The SOx removal efficiency will be established in the operating permit based on the stack tests results of Source ID P301.
15. (a) At least 60 days prior to the performance of the stack testing required by this plan approval, a test plan shall be submitted to the Department for evaluation. The plan shall contain a description of the proposed test methods and dimensioned drawings or sketches showing the test port locations.
(b) The Department shall be given at least 15 days advance notice of the scheduled dates for the performance of the stack testing required by this plan approval.
(c) Within 60 days of the completion of the stack tests required by this plan approval, two copies of the test report shall be submitted to the Department. This report shall contain the results of the tests, a description of the testing and analytical procedures actually used in performance of the tests, all process and operating data collected during the tests, a copy of all raw data, and a copy of all calculations generated during data analysis.
16. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, Source ID P302 shall be a natural gas/waste heat fired Lingl chamber dryer and shall be equipped with four Eclipse Minnox burners each rated at 3.00 mmBtu/hr. Only three of the four burners shall be operated at anytime.
17. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the NOx emissions from the exhaust of Source ID P302 shall not exceed 10 ppm, 0.11 lbs/hr and 0.47 ton in any 12-consecutive month period.
18. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, Source ID P303 shall be a natural gas fired Eclipse preheater and shall be equipped with a Minnox burner rated at 3.00 mmBtu/hr.
19. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the NOx emissions from the exhaust of Source ID P303 shall not exceed 10 ppm, 0.04 lbs/hr and 0.16 ton in any 12-consecutive month period.
20. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, Source ID P303 shall only be fired on natural gas.
21. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, The PM emissions from Source ID P304 shall be controlled by a Donaldson Torit model DFO 4-48 cartridge collector (ID C304). Source ID P304 is a grinding operation consisting of the following sources:
- 25` by 8` wide feed hopper
- 30` by 36" apron feeder
- 36" by 30` Dribble Belt Conveyor
- 30" by 112` Conveyor C1
- 30" by 60` Conveyor C2
- 30" by 51` Conveyor C3
- 30" by 41` Conveyor C4
- 30" by 85` Conveyor C5
- 30" by 61` Conveyor C6
- 30" by 73` Conveyor C7
- 30" by 60` Conveyor C8
- 30" by 52` Conveyor C9
- 30" by 16` Conveyor C10
- 30" by 95` Conveyor C11
- 30" by 18` Silo Discharge Conveyor
- 30" by 18` Silo Discharge Conveyor
- 5` by 10` double deck scalping screen
- Steadman model GS4260-AR/HC-T-H-A impact crusher rated at 200 tpy
- Three 5` by 8` single deck Deister finishing screens
- Two 100 ton capacity storage silos22. Source ID P304 is subject to 40 CFR Part 60 Subpart OOO §§ 60.670--60.676. The permittee shall comply with all applicable requirements of 40 CFR Part 60, 60.670--60.676.
23. The permittee shall comply with all recordkeeping and reporting requirements specified in 40 CFR Part 60, 60.676 for Source ID P304.
24. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the PM emissions in the exhaust of control device ID C304 associated with Source ID P304 shall not exceed 0.005 grains per dry standard cubic foot, 0.29 lbs/hr and 0.29 ton in any 12-consecutive month period.
25. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, all conveyors of Source ID P304 shall be completely covered unless otherwise completely enclosed in the building.
26. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, control device ID C304 associated with Source ID P304 shall be equipped with instrumentation which continuously monitors the pressure drop across ID C304. Additionally, the permittee shall record the pressure drop across ID C304 at least once per day. These records shall be retained for a minimum of 5 years and shall be provided to the Department upon request.
27. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the air compressors which supplies compressed air to the cartridge collector associated with Source ID P304 shall be equipped with an air dryer and oil trap.
28. The permittee shall maintain records of supporting calculations on a monthly basis to verify compliance with the PM emission limitations for Source ID P304.
29. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the permittee shall keep on hand a sufficient quantity of spare cartridges for the cartridge collector associated with Source ID P304 in order to be able to immediately replace any cartridge requiring replacement.
30. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the PM emissions from Source ID P305 shall be controlled by a Donaldson Torit model DFO 4-48 cartridge collector (ID C304). Source ID P305 is a production operation consisting of the following sources AutoBrick Machine System 46H (consisting of a pre pug mill, a pug mill and a brick machine) and an AutoBrick Machines System 24H (consisting of a pre pug mill, a pug mill and a brick machine).
31. Source ID P305 is subject to 40 CFR Part 60 Subpart OOO §§ 60.670--60.676. The permittee shall comply with all applicable requirements of 40 CFR Part 60, 60.670--60.676.
32. The permittee shall comply with all recordkeeping and reporting requirements specified in 40 CFR Part 60 § 60.676 for Source ID P305.
33. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the PM emissions in the exhaust of control device ID C304 associated with Source ID P305 shall not exceed 0.005 grains per dry standard cubic foot, 0.29 lbs/hr and 0.29 ton in any 12-consecutive month period.
34. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, Control device ID C304 associated with Source ID P305 shall be equipped with instrumentation which continuously monitors the pressure drop across ID C304. Additionally, the permittee shall record the pressure drop across ID C304 at least once per day. These records shall be retained for a minimum of 5 years and shall be provided to the Department upon request.
35. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the permittee shall keep on hand a sufficient quantity of spare cartridges for the cartridge collector associated with Source ID P305 in order to be able to immediately replace any cartridge requiring replacement.
36. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the air compressors which supplies compressed air to the cartridge collector associated with Source ID P305 shall be equipped with an air dryer and oil trap.
37. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, Source ID P306 shall not be operated in excess of 500 hours in any 12-consecutive month period. Source ID P306 is a 500 kW GENERAC Power Systems, Inc. model SD-500 diesel fired generator.
38. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the sulfur content of the diesel fuel used to fire Source ID P306 shall not exceed 0.05% by weight. Compliance with this streamlined plan approval requirement assures compliance with the requirement specified in 40 CFR Part 60, 60.4207(a).
39. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the SOx emissions from Source ID P306 shall not exceed 0.31 lbs/hr and 0.08 ton in any 12-consecutive month period.
40. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the PM emissions from Source ID P306 shall not to exceed 0.08 grams per brake horsepower-hr, 0.11 lbs/hr and 0.03 ton in any 12-consecutive month period. Compliance with this streamlined plan approval requirement assures compliance with the requirement specified in 40 CFR Part 60, 60.4202(a)(2).
41. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the CO, NOx and VOCs emissions shall not exceed 4.03 grams/brake hp-hr, 3.52 grams/brake hp-hr and 0.05 grams/brake hp-hr, respectively. Compliance with this streamlined plan approval requirement assures compliance with the requirement specified in 40 CFR Part 60, 60.4202(a)(2).
42. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the CO, NOx and VOCs emissions shall not exceed 0.19 ton, 1.47 tons and 0.01 ton in any 12-consecutive month period respectively.
43. Under the BAT requirements of 25 Pa. Code §§ 127.1 and 127.12, the NOx + nonmethane hydrocarbons from the exhaust associated with Source ID P306 shall not exceed 5.4 grams per kW-hr. Compliance with this streamlined plan approval requirement assures compliance with the requirement specified in 40 CFR Part 60, 60.4202(a)(2).
44. Source ID P306 is subject to 40 CFR Part 60, Subpart IIII, 60.4200--60.4219. The permittee shall comply with all applicable requirements of 40 CFR Part 60, 60.4200--60.4219.
45. The permittee shall keep records of the amount of hours Source ID P306 is operated each month in order to verify compliance with the 12-consecutive month period operating restriction. Additionally, the permittee shall keep records of the supporting calculations on a monthly basis which verify compliance with the SOx, NOx, CO, VOC and PM emission limitations.
46. The SOx emissions from all sources at the facility shall not equal or exceed 250 tons in any 12-consecutive month period.
47. The permittee shall maintain accurate and comprehensive records of the following:
- Monthly amount of bricks produced by Source ID P301.
- Monthly amount of brick produced by the existing kiln No. 1 and kiln No. 2 (Source IDs P101 and P201 in TVOP 49-00033).
- Monthly amount of clay/shale processed through Source ID P301.
- Monthly amount of each type of clay/shale processed through existing kiln No. 1 and kiln No. 2 (Source IDs P101 and P201 in TVOP 49-00033).
- Representative quarterly material composition analyses identifying the percentage (by weight) of fluorine, chlorine and sulfur contained in the clay/shale used in Source ID P301.
- The SOx emissions from all sources at the facility on a monthly basis, which include detailed emissions calculations to verify compliance with the SOx emissions limitation from all sources at the facility.Additionally, the records shall be used to determine the monthly emission of hydrogen fluoride, hydrogen chloride and SOx from Source ID P301 and the existing kiln No. 1 and kiln No. 2 (Source IDs P101 and P201 in TVOP 49-00033). These records shall be retained for a minimum of 5 years and shall be presented to the Department upon request. Monthly records generated to verify the emission limitations shall be submitted to the Department on a quarterly basis no later than 60 days following the respective calendar quarter (reports due on March 1, June 1, September 1 and December 1).
A copy of the plan approval application is available for public review between 8 a.m. and 4 p.m. at the Department's Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review may be made by calling the Department at (570) 327-3693. Written comments or requests for a public hearing should be directed to Muhammad Q. Zaman, Manager, Facilities Permitting Section, Department of Environmental Protection, Air Quality Program, Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701, (570) 327-0512.
08-399-023G: Osram Sylvania Products, Inc. (Hawes Street, Towanda, PA 18848-0504) for installation and operation of a fabric collector, a Flex Kleen model 84-WRS-48 (ID C306A), and an absolute filter (ID C306B) associated with the cobalt powder department (Source ID 306), at their facility located in North Towanda Township, Bradford County. The PM emissions from the cobalt powder process will be controlled by the proposed fabric collector and absolute filter. The existing fabric collector and filter associated with the cobalt powder department will be removed from the facility.
The Department of Environmental Protection's (Department) review of the information contained in the application submitted by OSRAM indicates that the cobalt powder process controlled by the proposed fabric collector and filter will comply with all applicable air quality requirements pertaining to air contamination sources and the emission of air contaminants, including the fugitive air contaminant emission requirement of 25 Pa. Code § 123.1, the PM emission limitation of 25 Pa. Code § 123.13, and the visible emission limitation of 25 Pa. Code § 123.41. The plan approval, if issued, will subsequently be incorporated in an operating permit by means of an administrative amendment in accordance with 25 Pa. Code § 127.450 at a later date.
Based upon this finding, the Department proposes to issue a plan approval for the installation of the fabric collector and absolute filter to control PM emissions from existing cobalt powder process. The following is a summary of the conditions the Department proposes to place in the plan approval to ensure compliance with all applicable regulatory requirements:
1. Source ID 306 consists of the following grade mix powder equipment:
a. Cobalt Powder Cooling Hood.
b. Despatch Electric Drying Oven.
c. Gruenberg Electric Drying Oven No. 1.
d. Gruenberg Electric Drying Oven No. 2.
The PM emissions from Source ID 306 shall be controlled by the Flex Kleen model 84-WRS-48 fabric collector (ID C306A) which incorporates an Absolute Filter (ID C306B) in its exhaust duct.
2. The Flex Kleen model 84-WRS-48 fabric collector (ID C306A) and the Absolute Filter (ID C036B) associated with Source ID 306 shall be each equipped with instrumentation to continuously monitor the pressure drop across the collector and filter.
3. The permittee shall record the pressure drop across the Flex Kleen model 84-WRS-48 fabric collector (ID C306A) and Absolute Filter (ID C306B) at least once per day. These records shall be kept for a minimum of 5 years and be presented to the Department upon request.
4. The permittee shall keep on hand a sufficient quantity of spare fabric collector bags and filters for IDs C306A and C306B associated with Source ID 306 in order to be able to immediately replace any bag or filter requiring replacement.
5. The Flex Kleen model 84-WRS-48 fabric collector (IDC306A) and Absolute Filter (ID C306B) shall maintain an efficiency of at least 99% for PM. The inlet PM emissions into the Flex Kleen model 84-WRS-48 fabric collector (ID C306A) shall not exceed 0.0323 pound per hour.
6. No person may permit the emission into the outdoor atmosphere of PM from the exhaust of ID C306B associated with Source ID 306 in a manner that the concentration in the effluent gas exceeds 0.04 grains per dry standard cubic foot.
A copy of the plan approval application and the Department's review is available for public review between 8 a.m. and 4 p.m. at the Department's Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701. Appointments for scheduling a review may be made by calling the Department at (570) 327-3693. Written comments or requests for a public hearing should be directed to Muhammad Q. Zaman, Manager, Facilities Permitting Section, Department of Environmental Protection, Air Quality Program, Northcentral Regional Office, 208 West Third Street, Suite 101, Williamsport, PA 17701, (570) 327-0512.
Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481, George Monasky, New Source Review Chief, (814) 332-6940.
20-194E: Lord Corporation--Saegertown Operations (601 South Street, Saegertown, PA 16433-1050) for authorization to install a new 1,500 gallon reactor vessel described in Saegertown Borough, Crawford County.
Under 25 Pa. Code §§ 127.44(a) and 127.424(b), the Department of Environmental Protection (Department) intends to issue a Plan Approval for their plant located in Saegertown Borough, Crawford County. This plan approval will authorize the applicant to install a new 1,500 gallon reactor vessel described in the applicant's application of December 20, 2007. The Plan Approval will subsequently be incorporated into the facility's Operating Permit through an administrative amendment in accordance with 25 Pa. Code § 127.450.
The source shall not exceed the emissions restriction limits of 1.1 tons of HAPs per year, 1.0 ton of VOCs per year and 0.2 ton of hydrogen bromide per year. The reactor is equipped with a condenser and a caustic scrubber. The facility will demonstrate compliance with the emission restrictions by keeping records of the emissions based on a 12-month rolling total.
Copies of the application, the Department's analysis, and other documents used in the evaluation are available for public inspection between 8 a.m. and 4 p.m. weekdays at the address shown. To make an appointment, contact Records Management at (814) 332-6340, for an appointment.
Anyone wishing to provide the Department with additional information they believe should be considered may submit the information to the address shown. Comments must be received, by the Department, within 30 days of the last day of publication. Written comments should include the following:
1. Name, address and telephone number of the person submitting comments.
2. Identification of the proposed Plan Approval No. 20-194E.
3. Concise statement regarding the relevancy of the information or any objections to issuance of the Plan Approval.
A public hearing may be held, if the Department, in its discretion, decides that such a hearing is warranted on the comments received during the public comment period. Persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in a local newspaper of general circulation or the Pennsylvania Bulletin or by telephone, where the Department determines such notification is sufficient. Written comments or requests for a public hearing should be directed to John Guth, Regional Air Quality Manager, Department of Environmental Protection, Northwest Regional Office, 230 Chestnut Street, Meadville, PA 16335, (814) 332-6940.
42-158M: Temple Inland, Inc.--Mt. Jewett Complex (R. R. 1, Hutchins Road, Mt. Jewett, PA 16740) to authorize the applicant to recirculate the exhaust gases from the second stage dryer, installation of a new cyclone and a second baghouse in Mt. Jewett Township, McKean County.
Under 25 Pa. Code §§ 127.44(a) and 127.424(b), the Department of Environmental Protection (Department) intends to issue a Plan Approval for their plant located in Mt. Jewett Township, McKean County. This plan approval will authorize the applicant to recirculate the exhaust gases from the second stage dryer, installation of a new cyclone and a second baghouse as described in the applicant's application of November 21, 2007. The Plan Approval will subsequently be incorporated into the facility's Operating Permit through an administrative amendment in accordance with 25 Pa. Code § 127.450.
The emissions restrictions from first stage fiber dryer have been reduced to: 121.44 tons CO per year, 9.58 tons SOx year, 40.71 tons VOCs per year and 19.12 tpy of PM/PM10. The facility shall follow the current NOx PAL emission restrictions. The facility must comply with the applicable requirements of the Plywood Composite Wood Product MACT (40 CFR 63, Subpart DDDD).
Copies of the application, the Department's analysis, and other documents used in the evaluation are available for public inspection between 8 a.m. and 4 p.m. weekdays at the address shown. To make an appointment, contact Records Management at (814) 332-6340, for an appointment.
Anyone wishing to provide the Department with additional information they believe should be considered may submit the information to the address shown. Comments must be received, by the Department, within 30 days of the last day of publication. Written comments should include the following:
1. Name, address and telephone number of the person submitting comments.
2. Identification of the proposed Plan Approval No. 42-158M.
3. Concise statement regarding the relevancy of the information or any objections to issuance of the Plan Approval.
A public hearing may be held, if the Department, in its discretion, decides that such a hearing is warranted on the comments received during the public comment period. Persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in a local newspaper of general circulation or the Pennsylvania Bulletin or by telephone, where the Department determines such notification is sufficient. Written comments or requests for a public hearing should be directed to John Guth, Regional Air Quality Manager, Department of Environmental Protection, Northwest Regional Office, 230 Chestnut Street, Meadville, PA 16335, (814) 332-6940.
[Continued on next Web Page]
No part of the information on this site may be reproduced for profit or sold for profit.This material has been drawn directly from the official Pennsylvania Bulletin full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.