GENERALLY

§ 403.1. Scope.

   (a)  Application. The Uniform Construction Code applies to the construction, alteration, repair, movement, equipment, removal, demolition, location, maintenance, occupancy or change of occupancy of every building or structure which occurs on or after April 9, 2004, and all existing structures that are not legally occupied.

   (b)  Exclusions. The Uniform Construction Code does not apply to:

   (1)  New buildings or renovations to existing buildings for which an application for a permit was made to the Department or a municipality before April 9, 2004.

   (2)  New buildings or renovations to existing buildings on which a contract for design or construction was signed before April 9, 2004.

   (3)  The following structures if the structure has a building area less than 500 square feet and is accessory to a detached one-family dwelling:

   (i)  Carports.

   (ii)  Detached private garages.

   (iii)  Greenhouses.

   (iv)  Sheds.

   (4)  An agricultural building defined under section 103 of the act (35 P. S. § 7210.103).

   (5)  Manufactured or industrialized housing shipped from the factory under section 901(a) of the act (35 P. S. § 7210.901(a)) as provided in § 403.25 (relating to manufactured and industrialized housing).

   (6)  Installation of tubing, piping, propane gas burning appliances, equipment or fixtures related to liquefied petroleum gas under the Propane and Liquefied Petroleum Gas Act (35 P. S. §§ 1329.1--1329.19).

   (7)  Construction of individual sewage disposal systems under 25 Pa. Code Chapter 73 (relating to onlot sewage treatment facilities).

   (c)  Prior permits and construction.

   (1)  A permit issued under construction regulations before April 9, 2004, remains valid and the construction of the building or structure may be completed in accordance with the approved permit. The permit is invalid unless the construction commenced within 2 years of permit issuance or a time period specified by municipal ordinance, whichever is less. The permit holder shall acquire a new permit under section 104(c) of the act (35 P. S. § 7210.104(c)) if the permit was not actively prosecuted during this time period.

   (2)  Construction may be completed without a permit under section 104(c)(2) of the act where construction of a building or structure commenced before April 9, 2004, and a permit was not required at that time.

   (3)  The legal occupancy of a structure existing on April 9, 2004, may continue without change except where the Uniform Construction Code provides otherwise.

   (d)  The Uniform Construction Code applies to the construction of a residential building or structure governed by a homeowner's or community association under section 104(d)(2)(ii) of the act.

   (e)  An electrical provision of the Uniform Construction Code does not apply to a dwelling unit utilized by a member of a recognized religious sect if a code administrator grants an exemption under section 901(b) of the act (35 P. S. § 7210.901(b)) as follows:

   (1)  The permit applicant shall file an application with the code administrator stating the manner in which an electrical provision of the Uniform Construction Code conflicts with the applicant's religious beliefs. The application shall also contain an affidavit by the applicant stating:

   (i)  The permit applicant is a member of a religious sect.

   (ii)  The religious sect has established tenets or teachings which conflict with an electrical provision of the Uniform Construction Code.

   (iii)  The permit applicant adheres to the established tenets or teachings of the sect.

   (iv)  The dwelling unit will be used solely as a residence for the permit applicant and the applicant's household.

   (2)  The code administrator shall grant the application for the exemption if made in accordance with paragraph (1).

   (3)  If the permit applicant receives an exemption for a dwelling unit under section 901(b) of the act and the applicant subsequently sells or leases the dwelling unit, the applicant shall bring the dwelling unit into compliance with the provision of the Uniform Construction Code from which it was exempted prior to the dwelling unit being sold or leased unless the prospective subsequent owner or lessee files an affidavit in compliance with paragraph (1).

§ 403.2.  Other statutes or ordinances.

   (a)  Under section 104(d)(1) of the act (35 P. S. § 7210.104(d)(1)), the provisions of the Uniform Construction Code listed in § 403.21 (relating to Uniform Construction Code) preempt and rescind construction standards provided by a statute, local ordinance or regulation. The recission or preemption does not apply to ordinances in effect on July 1, 1999, or reenactments of simultaneously repealed ordinances which were originally adopted before July 1, 1999, which contain provisions which meet or exceed the Uniform Construction Code under section 303(b)(1) of the act (35 P. S. § 7210.303 (b)(1)).

   (b)  Under section 303(a)(2) of the act, a municipal building code ordinance provision in effect in or adopted by a city of the first class on or before January 1, 1998, shall remain in effect until December 31, 2003. The provisions of the ordinance which do not comply with the Uniform Construction Code on December 31, 2003, will be amended to provide for the minimum requirements of the Uniform Construction Code.

§ 403.3.  Building code official delegation.

   (a)  The Department, a municipality or third-party agency shall employ or contract with a building code official to enforce the act.

   (b)  A building code official may delegate his duties to a construction code official or current code administrator.

STANDARDS

§ 403.21. Uniform Construction Code.

   (a)  The Department adopts and incorporates by reference the following codes as the Uniform Construction Code:

   (1)  The provisions of Chapters 2--29 and 31--35 of the ''International Building Code.''

   (2)  The ''ICC Electrical Code.''

   (3)  The ''International Mechanical Code.''

   (4)  The ''International Fuel Gas Code.''

   (5)  The ''International Plumbing Code.''

   (6)  The ''International Residential Code.''

   (7)  The ''International Fire Code.''

   (8)  The ''International Energy Conservation Code.''

   (9)  Sections AE501--AE503 and AE601--AE605 of Appendix E of the ''International Residential Code.''

   (10)  The ''International Existing Building Code.''

   (11)  The ''International Urban-Wildland Interface Code.''

   (12)  Appendix E of the ''International Building Code.''

   (13)  Appendix H of the ''International Building Code.''

   (14)  Appendix G of the International Residential Code.''

   (b)  The codes and standards adopted under subsection (a) are part of the Uniform Construction Code to the prescribed extent of each code or standard. The provisions of the Uniform Construction Code apply if there is a difference between the Uniform Construction Code and the codes or standards adopted in subsection (a). This chapter's administrative provisions govern under § 403.27(e) (relating to applicability and use of standards) if there is a conflict with the provisions of the codes relating to administration incorporated under subsection (a).

   (c)  Appendices to a code or standard listed in subsection (a) are not adopted in the Uniform Construction Code except for the provisions adopted in subsection (a)(9) and (12)--(14).

   (d)  Until December 31, 2003, a permit applicant shall use one of the following specifications for stairway construction in use groups R-3, within dwelling units in occupancies in use group R-2 and in occupancies in use group U which are accessory to an occupancy in use group R-3. The ''International Residential Code'' will apply to stairway construction in use group R-3 after December 31, 2003.

   (1)  Specifications utilized in place of exception 5 under section 1003.3.3.3 of the ''International Building Code'':

   (i)  The maximum riser height shall be 8 1/4 inches.

   (ii)  The minimum tread depth shall be 9 inches.

   (iii)  A 1-inch nosing shall be provided on all stairways with solid risers.

   (2)  Stairway specifications utilized in place of section R-314.2 of the ''International Residential Code'':

   (i)  The maximum riser height is 8 1/4 inches. There may be no more than a 3/8 inch variation in riser height within a flight of stairs. The riser height is to be measured vertically between leading edges of the adjacent treads.

   (ii)  The minimum tread depth is 9 inches measured from tread nosing to tread nosing.

   (iii)  The greatest tread depth within any flight of stairs may not exceed the smallest by more than 3/8 inch.

   (iv)  All treads may have a uniform projection of not more than 1 1/2 inches when solid risers are used.

   (v)  Stairways may not be less than 3 feet in clear width and clear headroom of 6 feet 8 inches shall be maintained for the entire run of the stair.

   (vi)  Handrails may project from each side of a stairway a distance of 3 1/2 inches into the required width of the stair.

   (e)  A permit applicant may utilize one of the following prescriptive methods to demonstrate compliance with the energy conservation requirements of the Uniform Construction Code. The standards are those listed for the climatic zone of this Commonwealth where the building or structure is located.

   (1)  The prescriptive methods for detached residential buildings contained in the current version of the ''International Energy Conservation Code'' compliance guide containing State maps, prescriptive energy packages and related software published by the United States Department of Energy, Building Standards and Guidelines Program (REScheckTM) or ''Pennsylvania's Alternative Residential Energy Provisions.''

   (2)  The prescriptive methods for all other buildings or structures contained in the current version of the ''International Energy Conservation Code'' compliance guide containing State maps, prescriptive packages and related software published by the United States Department of Energy, Building Standards and Guidelines Program (COMcheckTM).

   (f)  Construction of individual sewage disposal systems is governed under 25 Pa. Code Chapter 73 (relating to onlot sewage treatment facilities).

   (g)  The repair, alteration, change of occupancy, addition and relocation of existing buildings shall comply with Chapter 34 of the ''International Building Code'' or with the ''International Existing Building Code.''

§ 403.22. Health care facilities.

   (a)  A health care facility shall comply with all of the following under sections 104(d)(3) and 105(d)(1) of the act (35 P. S. §§ 7210.104(d)(3) and 7210.105(d)(1)):

   (1)  The Health Care Facilities Act.

   (2)  Regulations of the Department of Health in 28 Pa. Code Part IV (relating to health facilities).

   (3)  Building codes and regulations set forth in the applicable licensure laws and regulations under section 105(d) of the act (35 P. S. § 7210.105(d)).

   (4)  This chapter.

   (b)  Chapter 405 (relating to elevators and other lifting devices) always applies to health care facilities.

   (c)  In addition to the requirements of this chapter, a permit applicant for a health care facility shall obtain a license from the Department of Health under the Health Care Facilities Act and its regulations and comply with the Department of Health's license application procedures and its licensing regulations.

   (d)  A permit applicant for construction or alteration of a health care facility shall do all of the following:

   (1)  Submit construction or alteration plans to the Department of Health and obtain Department of Health approval before commencing construction or performing the alteration.

   (2)  Obtain approval from the Department of Health before occupancy of a new health care facility under 28 Pa. Code § 51.5 (relating to building occupancy).

   (3)  Obtain approval from the Department of Health before occupancy of an altered portion of an existing health care facility.

   (e)  A Department of Health inspector may inspect a health care facility site before, during and after construction to monitor compliance with Department of Health's health facility regulations.

   (f)  A building code official may not approve plans for a health care facility under this chapter unless the Department of Health has approved the plans.

   (g)  A building code official may not issue a certificate of occupancy for the health care facility under this chapter unless the Department of Health approved occupancy under 28 Pa. Code § 51.5.

   (h)  This section applies to construction or alteration of all health care facilities that the Department or a building code official review and approve under this chapter.

§ 403.23. Child day care facilities.

   (a)  A dwelling unit where child day care services are provided for less than 24 hours for 4 to 12 children is an R-3 occupancy if the dwelling unit is used primarily as a private residence and the provision of day care services is accessory to the principal use of the dwelling unit as a residence.

   (b)  A day care facility that is an R-3 occupancy under subsection (a) which provides day care services to 4--6 children shall comply with all of the following:

   (1)  Have a smoke detector on each floor and in the basement. The smoke detector may be powered by a nonreplacable, lithium battery listed by Underwriters Laboratories® that is warranted for 10 years and should sound an alarm when activated that is audible to persons in the unit's indoor child care space with all intervening doors closed. Where this type of detector is utilized, the unit owner of this detector shall keep the proof and date of purchase of the detector in the unit's fire drill logs.

   (2)  Have a portable fire extinguisher rated for Class B Fires in the kitchen and other cooking areas.

   (3)  Meet the exiting requirements for an R-3 occupancy and licensure under 55 Pa. Code Chapter 3290 (relating to family child day care homes).

   (c)  A day care facility that is an R-3 occupancy under subsection (a) which provides day care services to 7--12 children shall comply with all of the following:

   (1)  Have an interconnected smoke detector system.

   (2)  Have a fire extinguisher rated for Class B fires in the kitchen and other cooking areas.

   (3)  Meet the exiting requirements for an R-3 occupancy and licensure under 55 Pa. Code Chapter 3280 (relating to group child day care homes).

   (d)  All other child day care facilities shall be classified under Chapter 3 of the ''International Building Code.'' The facilities shall meet all Uniform Construction Code standards for these occupancy classifications.

§ 403.24. Historic buildings, structures and sites.

   A building code official may exclude an entire historic building or structure or part of the building or structure from compliance with the Uniform Construction Code if it meets all of the following conditions under section 902 of the act (35 P. S. § 7210.902):

   (1)  The building or structure is an existing building or structure, or a new building or structure that is not intended for residential use on an historic site.

   (2)  The building or structure is identified and classified by Federal or local government authority or the Historical and Museum Commission as an historic building or site.

   (3)  A building code official judges the building or structure or parts of the building and structure as safe and the exclusion is in the interest of public health, safety or welfare. The building code official shall apply the Uniform Construction Code to parts of the building or structure where its exclusion is not within the interest of the public health, safety and welfare. A building code official may not waive the Uniform Construction Code's accessibility requirements under this section.

§ 403.25. Manufactured and industrialized housing.

   (a)  Manufactured housing is governed by the following under section 901(a) of the act (35 P. S. § 7210.901(a)):

   (1)  Except as provided in paragraph (2), the Uniform Construction Code does not apply to manufactured housing assembled by and shipped from the manufacturer and which bears a label which certifies that it conforms to Federal construction and safety standards adopted under the Housing and Community Development Act of 1974 (42 U.S.C.A. §§ 5401--5426).

   (2)  This chapter and sections AE501--AE503 and AE601--AE605 of Appendix E of the International Residential Code adopted under the Uniform Construction Code apply to the following:

   (i)  Site preparation.

   (ii)  Foundation construction.

   (iii)  Connection to utilities.

   (3)  The Uniform Construction Code applies to the following:

   (i)  Alteration or repair to the unit that does not fall within 24 CFR 3280.1--3280.904 (relating to manufactured home construction and safety standards) and the manufacturer's installation instructions after assembly and shipment by the manufacturer.

   (ii)  Additions to the unit after delivery to the site.

   (iii)  Construction, alteration, repair or change of occupancy if the manufactured housing is resold to a subsequent purchaser.

   (iv)  Construction, alteration, repair or change of occupancy if the original purchaser relocates the manufactured housing.

   (b)  Industrialized housing is governed by the following under section 901(a) of the act:

   (1)  Except as provided in subsection (b)(2), the Uniform Construction Code does not apply to industrialized housing assembled by and shipped from the manufacturer.

   (2)  The Uniform Construction Code applies to all of the following:

   (i)   Site preparation.

   (ii)  Foundation construction.

   (iii)  Utilities connection.

   (iv)  Construction, alteration or repair to the industrialized housing unit after installation.

   (v)  Construction, alteration, repair or occupancy if industrialized housing is resold to a subsequent purchaser.

   (vi)  Construction, alteration, repair or occupancy if industrialized housing is relocated.

   (c)  The Department of Community and Economic Development may enforce and take action under the Industrialized Housing Act (35 P. S. §§ 1651.1--1651.12) and the Manufactured Housing Construction and Safety Standards Authorization Act (35 P. S. §§ 1656.1--1656.9).

§ 403.26.  Swimming pools.

   (a)  A swimming pool, hot tub and spa which is accessory to a one- or two-family dwelling shall comply with all of the following:

   (1)  Chapter 41 of the ''International Residential Code.''

   (2)  Appendix G of the ''International Residential Code.''

   (3)  Section 2406.2, paragraph 9 of the International Building Code (glazing in walls and fences enclosing indoor and outdoor swimming pools, hot tubs and spas).

   (4)  Section 3109.4 of the ''International Building Code (residential swimming pool enclosures).

   (b)  A swimming pool that is not accessory to a one- or two-family dwelling shall comply with this chapter, the ''American National Standards for Public Pools'' issued by ANSI and NSPI (ANSI/NSPI-1 1991) and the Public Bathing Law (35 P. S. §§ 672--680d).

   (c)  A hot tub or spa that is not accessory to a one- or two-family dwelling shall comply with this chapter and the ''American National Standard for Public Spas'' issued by ANSI and NSPI (ANSI/NSPI-2 1999).

§ 403.27. Applicability and use of standards.

   (a)  Portions of this chapter designate and incorporate portions of the following ICC 2003 copyrighted works:

   (1)  The ''International Building Code.''

   (2)  The ''International Residential Code.''

   (3)  The ''ICC Electrical Code.''

   (4)  The ''International Plumbing Code.''

   (5)  The ''International Mechanical Code.''

   (b)   The ''International Residential Code'' and the ''International Existing Building Code'' apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of detached one- and two-family dwellings and multiple single-family dwellings no more than 3 stories in height with a separate means of egress and their accessory structures.

   (c)  The ICC owns the copyrighted works in subsection (a). Reproduced with permission. All rights reserved.

   (d)  If different sections of this chapter specify different materials, method of construction or other requirements, the most restrictive material, method of construction or other requirement shall govern. The specific requirement of this part applies if there is a conflict between a general requirement and a specific requirement.

   (e)  This chapter governs if there is a conflict between this chapter and the provisions of the codes relating to administration incorporated under § 403.21(a) (relating to Uniform Construction Code).

   (f)  A provision of the ''International Mechanical Code'' does not apply if the provision conflicts with the Boiler and Unfired Pressure Vessel Law (35 P. S. §§ 1331.1--1331.9).

PERMIT AND INSPECTION PROCESS FOR COMMERCIAL CONSTRUCTION

§ 403.41. Commercial construction.

   This section and §§ 403.42--403.48 apply to the Department and municipalities electing to enforce the Uniform Construction Code under § 403.102 (relating to municipalities electing to enforce the Uniform Construction Code).

§ 403.42. Permit requirements and exemptions.

   (a)  An owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a commercial building, structure and facility or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical, or plumbing system regulated by the Uniform Construction Code shall first apply to the building code official and obtain the required permit under § 403.42a (relating to permit application).

   (b)  Emergency repairs or replacement of equipment may be made without first applying for a permit if a permit application is submitted to the building code official within 3 business days of the repair or replacement.

   (c)  A permit is not required for the exceptions listed in § 403.1(b) (relating to scope) and the following construction as long as the work does not violate a law or ordinance:

   (1)  Building construction for the following:

   (i)  Fences that are not over 6 feet high.

   (ii)  Oil derricks.

   (iii)  Retaining walls, which are not over 4 feet in height measured from the lowest level of grade to the top of the wall, unless it is supporting a surcharge or impounding Class I, II or III-A liquids.

   (iv)  Water tanks supported directly upon grade if the capacity does not exceed 5,000 gallons and the ratio of height to diameter or width does not exceed 2 to 1.

   (v)  Sidewalks and driveways not more than 30 inches above grade and that are not located over a basement or story below it and which are not part of an accessible route.

   (vi)  Painting, papering, tiling, carpeting, cabinets, counter tops and similar finishing work.

   (vii)  Temporary motion picture, television, and theater stage sets and scenery.

   (viii)  Prefabricated swimming pools accessory to a Group R-3 occupancy which are less than 24 inches deep, do not exceed 5,000 gallons and are installed entirely aboveground.

   (ix)  Shade cloth structures constructed for nursery or agricultural purposes that do not include service systems.

   (x)  Swings and other playground equipment accessory to one- or two-family dwellings.

   (xi)  Window awnings supported by an exterior wall which do not project more than 54 inches from the exterior wall and do not require additional support of group R-3 as applicable in the ''International Building Code,'' and Group U occupancies.

   (xii)  Movable cases, counters and partitions that are not over 5 feet 9 inches in height.

   (xiii)  Window replacement without structural change.

   (2)  Electrical work for the following:

   (i)  Minor repair and maintenance work that includes the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles.

   (ii)  Electrical equipment used for radio and television transmissions. The provisions of the Uniform Construction Code apply to equipment and wiring for power supply and the installation of towers and antennas.

   (iii)  The installation of a temporary system for the testing or servicing of electrical equipment or apparatus.

   (3)  The following gas work:

   (i)  A portable heating appliance.

   (ii)  Replacement of a minor part that does not alter approval of equipment or make the equipment unsafe.

   (4)  The following mechanical work or equipment:

   (i)   A portable heating appliance.

   (ii)   Portable ventilation equipment.

   (iii)  A portable cooling unit.

   (iv)  Steam, hot or chilled water piping within any heating or cooling equipment governed under the Uniform Construction Code.

   (v)   Replacement of any part that does not alter its approval or make it unsafe.

   (vi)   A portable evaporative cooler.

   (vii)  A self-contained refrigeration system containing 10 pounds or less of refrigerant and placed into action by motors that are not more than 1 horsepower.

   (5)  The following plumbing repairs:

   (i)  Stopping leaks in a drain and a water, soil, waste or vent pipe. The Uniform Construction Code applies if a concealed trap, drainpipe, water, soil, waste or vent pipe becomes defective and is removed and replaced with new material.

   (ii)  Clearing stoppages or repairing leaks in pipes, valves or fixtures, and the removal and installation of water closets, faucets and lavatories if the valves or pipes are not replaced or rearranged.

   (d)  An ordinary repair does not require a permit. The following are not ordinary repairs:

   (1)  Cutting away a wall, partition or portion of a wall.

   (2)  The removal or cutting of any structural beam or load-bearing support.

   (3)  The removal or change of any required means of egress, or rearrangement of parts of a structure affecting the egress requirements.

   (4)  The addition to, alteration of, replacement or relocation of any standpipe, water supply, sewer, drainage, drain leader, gas, soil, waste, vent or similar piping, electric wiring or mechanical.

   (e)  A permit is not required for the installation, alteration or repair of generation, transmission, distribution, metering or other related equipment that is, by established right, under the ownership and control of a public utility as the term ''public utility'' is defined in 66 Pa.C.S. § 102 (relating to definitions).

   (f)  A building code official may issue an annual permit instead of an individual permit for each alteration to an already approved electrical, gas, mechanical or plumbing installation. All of the following are required:

   (1)  The applicant shall regularly employ at least one qualified trades person in the building or structure owned or operated by the applicant.

   (2)  The applicant shall submit an application in accordance with § 403.42a(m).

   (3)  An annual permit holder shall keep detailed records of alterations made in accordance with the annual permit. The permit holder shall provide access to these records to the building code official.

§ 403.42a. Permit application.

   (a)  Applications for a permit required under § 403.42 (relating to permit requirements and exemptions) shall be submitted to the building code official in accordance with this section.

   (b)  A permit applicant shall submit an application to the building code official and attach construction documents, including plans and specifications, and information concerning special inspection and structural observation programs, Department of Transportation highway access permits and other data required by the building code official with the permit application. The applicant shall submit three sets of documents when the Department conducts the review.

   (c)  A licensed architect or licensed professional engineer shall prepare the construction documents under the Architects Licensure Law (63 P. S. §§ 34.1--34.22), or the Engineer, Land Surveyor and Geologist Registration Law (63 P. S. §§ 148--158.2). An unlicensed person may prepare design documents for the remodeling or alteration of a building if there is no compensation and the remodeling or alteration does not relate to additions to the building or changes to the building's structure or means of egress.

   (d)  A building code official may require submission of additional construction documents in special circumstances.

   (e)  The permit applicant shall submit construction documents in a format approved by the building code official. Construction documents shall be clear, indicate the location, nature and extent of the work proposed, and show in detail that the work will conform to the Uniform Construction Code.

   (f)  All of the following fire egress and occupancy requirements apply to construction documents:

   (1)  The permit applicant shall submit construction documents that show in sufficient detail the location, construction, size and character of all portions of the means of egress in compliance with the Uniform Construction Code.

   (2)  The construction documents for occupancies other than Groups R-2 and R-3 shall contain designation of the number of occupants to be accommodated on every floor and in all rooms and spaces.

   (3)  The permit applicant shall submit shop drawings for a fire protection system that indicates conformance with the Uniform Construction Code in accordance with the following:

   (i)  The shop drawings shall be approved by the building code official before the start of the system installation.

   (ii)  The shop drawings must contain the information required by the referenced installation standards contained in Chapter 9 of the ''International Building Code.''

   (g)  Construction documents shall contain the following information related to the exterior wall envelope:

   (1)  Description of the exterior wall envelope indicating compliance with the Uniform Construction Code.

   (2)  Flashing details.

   (3)  Details relating to intersections with dissimilar materials, corners, end details, control joints, intersections at roof, eaves, or parapets, means of drainage, water-resistive membrane and details around openings.

   (h)  Construction documents shall contain a site plan that is drawn to scale. The building code official may waive or modify the following site plan requirements if the permit application is for an alteration or repair or if waiver or modification is warranted. Site plan requirements include all of the following:

   (1)  The size and location of new construction and existing structures on the site.

   (2)  Accurate boundary lines.

   (3)  Distances from lot lines.

   (4)  The established street grades and the proposed finished grades.

   (5)  If the construction involves demolition, the site plan shall indicate construction that is to be demolished and the size and location of existing structures and construction that will remain on the site or plot.

   (6)  Location of parking spaces, accessible routes, public transportation stops and other required accessibility features.

   (i)  A permit applicant shall submit certifications required in the ''International Building Code'' for construction in a flood hazard area to the building code official.

   (j)  A permit applicant shall identify, on the application, the name and address of the licensed architect or engineer in responsible charge. The permit applicant shall notify the building code official in writing if another licensed architect or engineer assumes responsible charge.

   (k)  The permit applicant shall describe an inspection program, identify a person or firm who will perform special inspections and structural observations if section 1704 or 1709 of the ''International Building Code'' requires special inspections or structural observations for the construction.

   (l)  A building code official may waive or modify the submission of construction documents, that are not required to be prepared by a licensed architect or engineer, or other data if the nature of the work applied for does not require review of construction documents or other data to obtain compliance with the Uniform Construction Code. The building code official may not waive the submission of site plans that relate to accessibility requirements.

   (m)  An applicant for an annual permit under § 403.42(f) shall complete an application and provide information regarding the system that may be altered and the date that approval was previously provided for the approved electrical, gas, mechanical or plumbing installation.

   (n)  A permit applicant shall comply with the permit, certification or licensure requirements of the following laws applicable to the construction:

   (1)  The Boiler and Unfired Pressure Vessel Law (35 P. S. §§ 1331.1--1331.19).

   (2)  The Propane and Liquefied Petroleum Gas Act (35 P. S. §§ 1329.1--1329.19).

   (3)  The Health Care Facilities Act.

   (4)  The Older Adult Daily Living Centers Licensing Act (62 P. S. §§ 1511.1--1511.22).

§ 403.43. Grant, denial and effect of permits.

   (a)  A building code official shall grant or deny a permit application, in whole or in part, within 30 business days of the filing date. Reasons for the denial shall be in writing and sent to the applicant. The building code official and the permit applicant may agree in writing to extend the deadline by a specific number of days. A building code official may establish a different deadline to consider applications for a permit in an historic district.

   (b)  A building code official shall examine the construction documents and shall determine whether the construction indicated and described is in accordance with the Uniform Construction Code and other pertinent laws or ordinances as part of the application process.

   (c)  A building code official shall stamp or place a notation on each page of the set of reviewed construction documents that the documents were reviewed and approved for Uniform Construction Code compliance before the permit is issued. The building code official shall clearly mark any required nondesign changes on the construction documents. The building code official shall return a set of the construction documents with this notation and any required changes to the applicant. The permit holder shall keep a copy of the construction documents at the work site open to inspection by the construction code official or an authorized representative.

   (d)  A building code official may not issue a permit for any property requiring access to a highway under the Department of Transportation's jurisdiction unless the permit contains notice that a highway occupancy permit is required under section 420 of the State Highway Law (36 P. S. § 670-420) before driveway access to a Commonwealth highway is permitted.

   (e)  A building code official may issue a permit for the construction of the foundations or other parts of a building or structure before the construction documents for the whole building or structure are submitted if the permit applicant previously filed adequate information and detailed statements for the building or structure under the Uniform Construction Code. Approval under this section is not assurance that the building code official will issue a permit for the entire building or structure.

   (f)  Issuance of a permit does not bar prosecution or other legal action for violations of the act, the Uniform Construction Code or a construction ordinance. A building code official may suspend or revoke a permit issued under the Uniform Construction Code when the permit holder does not make the required changes directed by the building code official under subsection (c), when the permit is issued in error, on the basis of inaccurate or incomplete information or in violation of any act, regulation, ordinance or the Uniform Construction Code.

   (g)  A permit becomes invalid unless the authorized construction work begins within 180 days after the permit's issuance or if the authorized construction work permit is suspended or abandoned for 180 days after the work has commenced. A permit holder may submit a written request for an extension of time to commence construction for just cause. The building code official may grant extensions of time to commence construction in writing. A permit may be valid for no more than 5 years from its issue date.

   (h)  The permit holder shall keep a copy of the permit on the work site until the completion of the construction.

   (i)  A permit applicant may request extensions of time or variances or appeal a building code official's action on the permit application to a board of appeals under § 403.122 (relating to appeals, variances and extensions of time).

   (j)  A board of appeals may not rule on requests for extensions of time, variances or appeals relating to this chapter's accessibility requirements. The Secretary has the exclusive power to grant modifications and extensions of time and decide issues of technical infeasibility under § 403.142 (relating to Accessibility Advisory Board)

   (k)   A building code official may allow deferred submittals of portions of the design of the building and structure from the time of the application until a specified time set by the building code official. All of the following apply to deferred submittals:

   (1)   The building code official shall provide prior approval of the deferral of any submittal items.

   (2)  A licensed architect or professional engineer in responsible charge shall list the deferred submittals on the construction documents for review by the building code official.

   (3)  A licensed architect or professional engineer shall first review submittal documents for deferred submittal items and place a notation on the documents that the architect or engineer reviewed the documents and that the documents are in general conformance with the design of the building or structure.

   (4)  Deferred submittal items may not be installed until the building code official approves the design and submittal documents for the deferred submittal items.

   (l)  Work shall be installed in accordance with the approved construction documents. The permit holder shall submit a revised set of construction documents for approval for changes made during construction that are not in accordance with the approved construction documents.

   (m)  A permit is not valid until the required fees are collected under §§ 401.2 and 401.2a (relating to Department fees; and municipal and third-party agency fees).

§ 403.44. Alternative construction materials and methods.

   (a)  Materials, products and methods of construction that were evaluated as meeting codes enumerated in § 403.21 (relating to Uniform Construction Code) by the ICC Evaluation Service, Inc. or an evaluation service accredited under the ''General Requirements for Bodies Operating Product Certification Systems'' issued by the ISO (ISO Guide 65) are approved for use. The use shall conform with the evaluation.

   (b)  Materials, equipment and devices bearing the label or listed by a testing laboratory or quality assurance agency accredited by the International Accreditation Service, Inc. or another agency accredited under the ''Calibration and Testing Laboratory Accreditation Systems-General Requirements for Operation and Recognition'' issued by ISO (ISO Guide 58) are approved for use if:

   (1)  The testing laboratory or quality assurance agency deemed the material as meeting Uniform Construction Code-required standards.

   (2)  The scope of accreditation is applicable to Uniform Construction Code-required standards.

   (c)  A new building or remodeling, alteration, addition or change of use and occupancy of an existing building which complies with the International Performance Code shall also be in compliance with the Uniform Construction Code.

§ 403.45. Inspections.

   (a)  A construction code official shall perform inspections to insure that the construction complies with the approved permit and the Uniform Construction Code.

   (b)  Before issuing a permit, a building code official may examine, or cause to be examined, buildings, structures, facilities or sites related to the permit application.

   (c)  The permit holder or an authorized agent shall notify the construction code official when work is ready for inspection and provide access for the inspection. The work shall remain accessible and exposed for inspection. A construction code official may inspect the construction and equipment only during normal hours at the construction site unless the permit holder or agent requests or agrees to another time. Inspections may be conducted under § 403.86 (relating to right of entry to inspect).

   (d)  A construction code official shall notify a permit holder if construction complies with the Uniform Construction Code or fails to comply with the Uniform Construction Code.

   (e)  A construction code official shall conduct a final inspection of the completed construction work and file a final inspection report, which indicates that all of the following areas met Uniform Construction Code requirements after a final inspection of the completed construction work:

   (1)  General building under § 401.7(6) (relating to certification category specification for building inspector).

   (2)  Electrical under § 401.7(7).

   (3)  Plumbing under § 401.7(9).

   (4)  Accessibility under § 401.7(11).

   (5)  Fire protection under § 401.7(13).

   (6)  Mechanical under § 401.7(8).

   (7)  Energy conservation under § 401.7(10).

§ 403.46. Certificate of occupancy.

   (a)  A building, structure or facility may not be used or occupied without a certificate of occupancy issued by a building code official.

   (b)  A building code official shall issue a certificate of occupancy within 5 business days after receipt of a final inspection report that indicates compliance with the Uniform Construction Code. The certificate of occupancy shall contain the following information:

   (1)  The permit number and address of the building, structure or facility.

   (2)  The permit holder's name and address.

   (3)  A description of the portion of the building, structure or facility covered by the occupancy permit.

   (4)  The name of the building code official who issued the occupancy permit.

   (5)  The applicable construction code edition applicable to the occupancy permit.

   (6)  The use and occupancy classification under Chapter 3 (Use and Occupancy Classification) of the ''International Building Code,'' when designated.

   (7)  The type of construction defined in Chapter 6 (Types of Construction) of the ''International Building Code,'' when designated.

   (8)  Special stipulations and conditions relating to the permit and board of appeals' decisions and variances for accessibility requirements granted by the Secretary.

   (9)  The date of the final inspection.

   (c)  A building code official may issue a certificate of occupancy for a portion of a building, structure or facility if the portion independently meets the Uniform Construction Code.

   (d)  A building code official may suspend or revoke a certificate of occupancy when the certificate was issued in error, on the basis of incorrect information supplied by the permit applicant or in violation of the Uniform Construction Code. Before a certificate of occupancy is revoked, a building owner may request a hearing before the board of appeals under § 403.122 (relating to appeals, variances and extensions of time).

§ 403.47. Public utility connections.

   (a)  A building code official may authorize the temporary connection of a building or system under construction to a utility source of energy, fuel or power.

   (b)  Connection to a public electric or gas utility for the completed construction may not occur unless the permit holder provides written proof to the utility company that the building or structure passed inspections under this chapter.

§ 403.48. Boilers.

   (a)  The Boiler and Unfired Pressure Law (35 P. S. §§ 1331.1--1331.19) and Chapter 3 (relating to boilers and unfired pressure vessels) govern the new installation, repair or replacement of a boiler or other pressure vessel.

   (b)  A permit under this chapter is not required for the installation, repair or replacement of a boiler or unfired pressure vessel under subsection (a). The building or structure containing the boiler or unfired pressure vessel shall comply with the Uniform Construction Code or the regulation or ordinance in effect at the time of its legal occupancy.

PERMIT AND INSPECTION PROCESS FOR RESIDENTIAL BUILDINGS

§ 403.61. Residential buildings.

   This subchapter and §§ 403.62--403.66 apply to municipalities electing to enforce the Uniform Construction Code under §  403.102 (relating to municipalities electing to enforce the Uniform Construction Code) and third-party agencies.

§ 403.62. Permit requirements and exemptions.

   (a)  An owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a residential building or erect, install, enlarge, alter, repair, remove, convert or replace an electrical, gas, mechanical or plumbing system regulated by the Uniform Construction Code shall first apply to the building code official and obtain the required permit under § 403.62a (relating to permit application).

   (b)  An emergency repair or replacement of equipment may be made without first applying for a permit if a permit application is submitted to the building code official within 3 business days of the repair or replacement.

   (c)  A permit is not required for the exceptions listed in § 403.1(b) (relating to scope) and the following construction if the work does not violate a law or ordinance:

   (1)  The following building construction, replacement or repairs:

   (i)  Fences that are no more than 6 feet high.

   (ii)  Retaining walls that are not over 4 feet in height measured from the lowest level of grade to the top of the wall unless the wall supports a surcharge.

   (iii)  Water tanks supported directly upon grade if the capacity does not exceed 5,000 gallons and the ratio of height to diameter or width does not exceed 2 to 1.

   (iv)  Sidewalks and driveways that are 30 inches or less above adjacent grade and not placed over a basement or story below it.

   (v)  Exterior or interior painting, papering, tiling, carpeting, flooring, cabinets, counter tops and similar finishing work.

   (vi)  Prefabricated swimming pools that are less than 24 inches deep.

   (vii)  Swings and other playground equipment accessory to a one- or two-family dwelling.

   (viii)  Window awnings supported by an exterior wall which do not project more than 54 inches from the exterior wall and do not require additional support.

   (ix)  Replacement of glass in any window or door. The replacement glass shall comply with the minimum requirements of the International Residential Code.

   (x)  Installation and replacement of a window, door, garage door, storm window and storm door in the same opening if the dimensions or framing of the original opening are not altered. The installation of means of egress and emergency escape windows may be made in the same opening, without altering the dimensions or framing of the original opening if the required height, width or net clear opening of the previous window or door assembly is not reduced.

   (xi)  Replacement of existing roof material that does not exceed 25% of the total roof area performed within any 12-month period.

   (xiii)  Replacement of existing siding.

   (xiv)  Repair or replacement of any part of a porch or stoop which does not structurally support a roof located above the porch or stoop.

   (xv)  Installation of additional roll or batt insulation.

   (xvi)  Replacement of exterior rain water gutters and leaders.

   (xvii)  Installation of an uncovered deck where the floor of the deck is no more than 30 inches above grade.

   (2)  Minor electrical work for the following:

   (i)  Replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles

   (ii)  Replacement of a receptacle, switch or lighting fixture rated at 20 amps or less and operating at less than 150 volts to ground with a like or similar item. This does not include replacement of receptacles in locations where ground-fault circuit interrupter protection is required.

   (iii)  Replacement of installed electrically operated equipment such as doorbells, communication systems and any motor operated device.

   (iv)  Installation, alteration or rearrangement of communications wiring.

   (v)  Replacement of dishwashers.

   (vi)  Replacement of kitchen range hoods.

   (vii)  Installation of battery-powered smoke detectors.

   (3)  The following gas work:

   (i)   Portable heating, cooking or clothes drying appliances.

   (ii)  Replacement of a minor part that does not alter approval of equipment or make this equipment unsafe.

   (iii)  A portable fuel cell appliance that is not connected to a fixed piping system and is not interconnected to a power grid.

   (4)  The following mechanical work or equipment:

   (i)   A portable heating appliance.

   (ii)  Portable ventilation appliances.

   (iii)  A portable cooling unit.

   (iv)  Steam, hot or chilled water piping within any heating or cooling equipment governed under the Uniform Construction Code.

   (v)  Replacement of any minor part that does not alter approval of equipment or make the equipment unsafe.

   (vi)  Self-contained refrigeration systems containing 10 pounds or less of refrigerant or that are put into action by motors 1 horsepower.

   (vii)  Portable evaporative cooler.

   (viii)  A portable fuel cell appliance that is not connected to a fixed piping system and is not interconnected to a power grid.

   (5)  The following plumbing work:

   (i)  Replacement of bib valves if the replacement hose bib valves are provided with an approved atmospheric vacuum breaker.

   (ii)  Refinishing of existing fixtures.

   (iii)  Replacement of ball cocks.

   (iv)  Repair of leaks.

   (v)  Clearance of stoppages.

   (vi)  Replacement of faucets or working parts of faucets.

   (vii)  Replacement of valves other than shower or combination shower/bath valves.

   (viii)  Replacement of traps.

   (ix)  Replacement of a water closet, lavatory or kitchen sink.

   (x)  Replacement of domestic clothes washers and dishwashers.

   (6)  The following heating, ventilation and air conditioning work:

   (i)   Replacement of motors, pumps and fans of the same capacity.

   (ii)  Repair and replacement of heating, supply and return piping and radiation elements which do not require rearrangement of the piping system.

   (iii)  Repair and replacement of duct work.

   (iv)  Repair and replacement of air conditioning equipment and systems.

   (v)  Repair and replacement of control devices for heating and air conditioning equipment.

   (vi)  Replacement of kitchen range hoods.

   (vii)  Replacement of clothes dryers if there is no change in fuel type, location or electrical requirements.

   (viii)   Replacement of stoves and ovens if there is no change in fuel type, location or electrical characteristics.

   (d)  An ordinary repair does not require a permit. The following are not ordinary repairs:

   (1)  Cutting away a wall, partition or portion of a wall.

   (2)  The removal or cutting of any structural beam or load-bearing support.

   (3)  The removal or change of any required means of egress, or rearrangement of parts of a structure affecting the egress requirements.

   (4)  The addition to, alteration of, replacement or relocation of any standpipe, water supply, sewer, drainage, drain leader, gas, soil, waste, vent or similar piping, electric wiring or mechanical.

   (e)  A permit is not required for the installation, alteration or repair of generation, transmission, distribution, metering or other related equipment that is, by established right, under the ownership and control of a public utility as the term ''public utility'' is defined in 66 Pa.C.S. § 102 (relating to the definitions).

[Continued on next Web Page]



No part of the information on this site may be reproduced for profit or sold for profit.