Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Code website reflects the Pennsylvania Code changes effective through 54 Pa.B. 1032 (February 24, 2024).

7 Pa. Code § 37.113. Design and construction in the nonfood products zone.

§ 37.113. Design and construction in the nonfood products zone.

 (a)  Safety and gear guards shall be removable for cleaning and inspection.

 (b)  External surfaces shall be free of open seams, gaps, crevices, unused holes and inaccessible recesses.

 (c)  Horizontal ledges and frame members shall be kept to a minimum. External angles shall be rounded and internal angles shall be avoided.

 (d)  Where lubrication of equipment is required provision shall be made to prevent leaking or dripping into the food product zone.



No part of the information on this site may be reproduced for profit or sold for profit.


This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.