34 Pa. Code § 47.121. Walks.

GROUNDS, BUILDINGS AND FACILITIES


§ 47.121. Walks.

 There shall be at least one walk serving each of the buildings as set forth in §  47.111 (relating to scope) conforming to the following specifications:

   (1)  Be at least 48 inches wide with a slope no portion of which is steeper than 5%.

   (2)  Be of a continuing common surface uninterrupted by steps or abrupt changes in grade.

   (3)  Blend to a common level whenever the walk crosses other walks, driveways or parking lots.

   (4)  Have a level platform at the building entrance which it serves and the platform shall be at least 5 feet square if a door swings out on to the platform or toward the walk; the platform shall extend at least 1 foot beyond each side of the doorway.

   (5)  Have a level platform at least 3 feet deep and 5 feet wide if the door does not swing on to the platform or toward the walk; the platform shall extend at least 1 foot beyond each side of the doorway.