AIR QUALITY


Plan approval and operating permit applications.

 The Department has developed an ''integrated'' plan approval, State Operating Permit and Title V Operating Permit program. This integrated approach is designed to make the permitting process more efficient for the Department, the regulated community and the general public. This approach allows the owner or operator of a facility to submit permitting documents relevant to its application for all sources related to a facility or a proposed project, affords an opportunity for public input, and provides for a decision on the issuance of the necessary permits.

 The Department received applications for Plan Approvals or Operating Permits from the following facilities. Copies of the application, the Department's analysis, all pertinent documents used in the evaluation of the application and subsequently prepared proposed plan approvals/operating permits are available for public review during normal business hours at the appropriate Department Regional Office. Appointments for scheduling a review must be made by calling the appropriate Department Regional Office. The address and phone number of the Regional Office is listed before the application notices.

 Persons wishing to file a written protest or provide comments or additional information, which they believe should be considered prior to the issuance of a permit, may submit the information to the Department's Regional Office. A 30-day comment period from the date of this publication will exist for the submission of comments, protests and information. Each submission must contain the name, address and telephone number of the person submitting the comments, identification of the proposed Plan Approval/Operating Permit including the permit number and a concise statement regarding the relevancy of the information or objections to issuance of the permit.

 A person wishing to request a hearing may do so during the 30-day comment period. A public hearing may be held, if the Department, in its discretion, decides that a hearing is warranted based on the information received. Persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper, the Pennsylvania Bulletin or by telephone, when the Department determines this type of notification is sufficient. Requests for a public hearing and any relevant information should be directed to the appropriate Department Regional Office.

 Permits issued to the owners or operators of sources subject to 25 Pa. Code Chapter 127, Subchapter D or E, or located within a Title V facility or subject to 25 Pa. Code § 129.51(a) or permits issued for sources with limitations on their potential to emit used to avoid otherwise applicable Federal requirements may be submitted to the United States Environmental Protection Agency for review and approval as a revision to the State Implementation Plan. Final Plan Approvals and Operating Permits will contain terms and conditions to ensure that the sources are constructed and operating in compliance with applicable requirements in the Air Pollution Control Act (35 P.S. §§ 4001—4015), 25 Pa. Code Chapters 121—145, the Federal Clean Air Act (42 U.S.C.A. §§ 7401—7671q) and regulations adopted under the Federal Clean Air Act.

 Persons with a disability who wish to comment and require an auxiliary aid, service or other accommodation to participate should contact the regional office listed before the application. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

PLAN APPROVALS


Plan Approval Applications Received under the Air Pollution Control Act (35 P.S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter B that may have special public interest. These applications are in review and no decision on disposition has been reached.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481.

Contact: Dave Balog, New Source Review Chief—Telephone: 814-332-6940.

16-132P: Clarion Boards, Inc. (143 Fiberboard Road, Shippenville, PA 16254) for the proposed exhausting of Source 105 to atmosphere; splitting Source 110 into Source 110 & 113; and the removal of Source 109 from the facility operating permit in Paint Township, Clarion County. This is a Title V facility.


Intent to Issue Plan Approvals and Intent to Issue or Amend Operating Permits under the Air Pollution Control Act (35 P.S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter B. These actions may include the administrative amendments of an associated operating permit.

Southeast Region: Air Quality Program, 2 East Main Street, Norristown, PA 19401.

Contact: James Beach, New Source Review Chief—Telephone: 484-250-5920.

09-0244: MM Metals USA, LLC (4000 Chemical Road, Plymouth Meeting, PA 19462) for of a new low-carbon ferrochrome (LC FeCr) alloy manufacturing facility to be located in Falls Township, Bucks County. Post-control Particulate Matter (PM), Volatile Organic Compound (VOC), Nitrogen Oxide (NOx), and Hazardous Air Pollutant (HAP) emissions are less than major source thresholds for the Philadelphia Metropolitan Area; the facility is classified as a Natural Minor Facility. The requirements of 40 CFR Part 63 Subpart RRR apply to the melt furnace operating as part of Aluminum Production. The melt furnace is classified as a Group 1 Furnace and is subject to the dioxins/furans-related requirements of Subpart RRR. The general opacity requirements of 40 CFR Part 63 Subpart YYYYYY apply to the plasma furnace operating as part of LC FeCr Production. The plan approval will include monitoring, testing, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

Northeast Region: Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18711-0790.

Contact: Raymond Kempa, New Source Review Chief—Telephone: 570-826-2507.

 Notice is hereby given in accordance with 25 Pa. Code §§ 127.44(b) and 127.424(b), that the Department of Environmental Protection (DEP) intends to issue a plan approval to Calpine Bethlehem, LLC (500 Delaware Avenue, Suite 600, Wilmington, DE 19801) to increase their hours of operation at their facility located in Bethlehem, Northampton County. The facility currently has a Title V Operating Permit No. 48-00076. Plan approval 48-00076E will subsequently be incorporated into the Title V Operating Permit through an administrative amendment in accordance with 25 Pa. Code § 127.450.

 Plan Approval No. 48-00076E will be for the increase in operational hours for the existing turbines by 100 hours/year for each turbine. The six turbines combined would be limited to 43,800 hours/year total for all six (based on 7,300 hours/year each). The Department's review of the information submitted by Calpine Bethlehem, LLC indicates that the proposal will meet all applicable air quality requirements pertaining to air contamination sources and the emission of air contaminants, including the BAT requirements. The company shall comply with 123.31 for malodorous emissions. The company shall comply with 123.41 for visible emissions. The turbines are subject to 40 CFR Part 60 Subpart KKKK requirements. CEMS will continue to be used to measure NOx, CO and O2 emissions. The Plan approval and Operating Permit will include testing, monitoring, record keeping, and reporting requirements designed to keep the sources operating within all applicable air quality requirements.

 Copies of the applications, DEP's analysis and other documents used in the evaluation of the application are available for public review during normal business hours at the Northeast Regional Office, 2 Public Square, Wilkes-Barre, PA 18711.

 Any person(s) wishing to provide DEP with additional information they believe should be considered prior to the issuance of this permit may submit the information to the address shown in the preceding paragraph. The submittal of written comment must contain the name, address and telephone number of the commentator, identification of the proposed Permit No. 48-00076E and a concise statement regarding the relevancy of the information or objections to the issuance of the permit.

 A public hearing may be held, if the Department of Environmental Protection, in its discretion, decides that such a hearing is warranted based on comments received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or the Pennsylvania Bulletin or by telephone, where DEP determines such notification is sufficient. Written comments or requests for a public hearing should be directed to Mr. Raymond Kempa, Env. Engineering Manager, New Source Review Section, 2 Public Square, Wilkes-Barre, PA 18701-1915, or 570-826-2511.

Southwest Region: Air Quality Program, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.

Contact: Ed Orris, P.E., New Source Review Chief Telephone: 412-442-4168.

04-00751A: Valmont Coatings, Inc. (9 South 12th Street, Midland, PA 15059-1603). Notice is hereby given in accordance with 25 Pa. Code §§ 127.44 and 127.45 that the Department of Environmental Protection (''Department'') intends to issue Air Quality Plan Approval: PA-04-00751A to Valmont Coatings, Inc. for installation and operation of a hot dip galvanizing process and pre-treatment cleaning operations in an enclosed building to be located at No. 9 South 12th Street, Midland in Midland Borough, Beaver County.

 The emissions from all sources are less than 3.0 tpy particulate matter (PM10), 2.0 tpy SOx, 12.0 tpy NOx, 20.0 tpy CO, 8.0 tpy VOC, 1.0 tpy of single HAP, and 2.5 tpy of combined (HAPs). The kettle particulate emissions will be controlled by a dust collector exhausting indoor with 95—99% efficiency.

 This authorization is subject to State regulations including 25 Pa. Code Chapters 123, 127, and 129. Plan approval conditions include monitoring requirements, work practice standards, associated recordkeeping, and reporting requirements. Once compliance with the Plan Approval is demonstrated, the applicant will be required to revise or submit a State Only Operating Permit (''SOOP'') application in accordance with 25 Pa. Code Subchapter F.

 The application, DEP's Review Memorandum, and the proposed permit are available for public review during normal business hours at DEP's Southwest Regional Office, 400 Waterfront Drive, Pittsburgh PA 15222. A file review can be scheduled through the DEP's website at https://www.dep.pa.gov/Citizens/PublicRecords/Pages/Informal-File-Review.aspx.

 A person may oppose the proposed Air Quality plan approval by filing a written protest with the Department or may submit written comments through Jesse S. Parihar via the U.S. Postal Service to the Pennsylvania Department of Environmental Protection, 400 Waterfront Drive, Pittsburgh, PA 15222; written comments may also be submitted via email to jparihar@pa.gov or via fax to 412.442.4194. Each set of written comments or protest must contain the name, address, and telephone number of the person submitting the comments or protest, identification of the proposed plan approval (04-00751A) and a concise statement of the objections to the plan approval issuance and the relevant facts upon which the objections are based.

 All comments must be received prior to the close of business 30 days after the date of this publication. A protest to the proposed action shall be filed with the Department within 30 days of the date that notice of the proposed action was published under 25 Pa. Code § 127.44 (relating to public notice).

 A public hearing may be held, if the Department, in its discretion, decides that such a hearing is warranted based on the information received. All persons who have properly filed a protest under 25 Pa. Code § 127.46 may appear and give testimony. The applicant, the protestant and other participants will be notified of the decision to hold a hearing by publication in the newspaper or by the Pennsylvania Bulletin, or by telephone, where the Department determines such notification by telephone is sufficient.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481.

Contact: Devendra Verma, New Source Review Chief—Telephone: 814-332-6940.

Department of Public Health, Air Management Services: 321 University Avenue, Philadelphia, PA 19104.

09-0244: MM Metals USA, LLC (4000 Chemical Road, Plymouth Meeting, PA 19462) for a new low-carbon ferrochrome (LC FeCr) alloy manufacturing facility to be located in Falls Township, Bucks County. Post-control Particulate Matter (PM), Volatile Organic Compound (VOC), Nitrogen Oxide (NOx), and Hazardous Air Pollutant (HAP) emissions are less than major source thresholds for the Philadelphia Metropolitan Area; the facility is classified as a Natural Minor Facility. The requirements of 40 CFR Part 63 Subpart RRR apply to the melt furnace operating as part of Aluminum Production. The melt furnace is classified as a Group 1 Furnace and is subject to the dioxins/furans-related requirements of Subpart RRR. The general opacity requirements of 40 CFR Part 63 Subpart YYYYYY apply to the plasma furnace operating as part of LC FeCr Production. The plan approval will include monitoring, testing, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

OPERATING PERMITS


Intent to Issue Title V Operating Permits under the Air Pollution Control Act (35 P.S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter G.

Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110.

Contact: Thomas Hanlon, Facilities Permitting Chief, 717-705-4862, Thomas Bianca, New Source Review Chief, 717-705-4863, or William Weaver, Regional Air Quality Manager, 717-705-4702.

22-05012: ArcelorMittal Steelton, LLC (215 South Front Street, Steelton, PA 17113-2538) for their steel manufacturing facility in Steelton Borough, Dauphin County. The Title V Operating Permit is undergoing a significant modification to incorporate a Reasonably Available Control Technology II (RACT II) plan.

 In accordance with 25 Pa. Code §§ 129.91—129.100, the Department has made a preliminary determination to approve a RACT II plan to be submitted as part of the State Implementation Plan (SIP) for Arcelor's steel manufacturing facility.

 The SIP revision does not adopt any new regulations. It incorporates the provisions and requirements contained in the amended RACT approval for the facility, which are determined to satisfy the requirements for the 1997, 2008 and 2015 National Ambient Air Quality Standards (NAAQS) for ozone.

 The proposed RACT II plan, if approved by DEP, will be issued as a significant modification to the facility's Title V operating permit (22-05012). The relevant RACT II requirements will also be submitted to the U.S. Environmental Protection Agency (EPA) for approval and incorporation into Pennsylvania's State Implementation Plan. Requirements that are not part of the RACT II approval will be excluded from the SIP submittal.

 The following is a summary of the proposed RACT II requirements for this facility that will be submitted to the EPA as part of the SIP:

 RACT II Case-by-Case Requirements

 I. Sources 232C (20" Mill Reheat Furnace) and 301 (35" Mill Reheat Furnaces 3 & 4).

 (a) The permittee shall perform an annual adjustment and/or tune-up on each unit which shall include the following:

 (1) Inspection, adjustment, cleaning or replacement of fuel-burning equipment, including the burners and moving parts necessary for proper operation as specified by the manufacturer.

 (2) Inspection of the flame pattern or characteristics and adjustments necessary to minimize emissions of NOx and VOC.

 (3) Inspection of the air-to-fuel ratio control system and adjustments necessary to ensure proper calibration and operation as specified by the manufacturer.

 (b) The company shall maintain a permanently bound log book or other method approved by the Department. This log shall contain at a minimum, the following information.

 (1) The date of the tuning procedure.

 (2) The name of the service company and technicians.

 (3) The final operating rate or load.

 (4) The final NOx and VOC emission rates.

 (5) The final excess oxygen rate.

 (6) Any other information required by this approval.

 (c) The annual adjustment for the boilers shall be in accordance with the EPA document ''Combustion Efficiency Optimization Manual for Operations of Oil and Gas-Fired Boilers'', September 1983 (EPA-340/1-83-023) or equivalent procedures approved in writing by the Department.

 (d) All adjustments and optimization of the units must minimize pollution and be in accordance with good air pollution control practices.

 II. Sources 401 (Soaking Pit Batteries 4-6) and 501A (# 207 DCEAF).

 (a) The permittee shall maintain and adhere to an operation and maintenance plan for Sources 401 and 501A, which shall address good operation and maintenance practices for the minimization of NOx (both sources) and VOC emissions (Source 501A), and/or manufacturer's operating specifications, including, for Source 501A measures to minimize the ambient air infiltration into the direct evacuation hoods.

 (b) The permittee shall maintain records of any maintenance or modifications performed on Sources 401 and 501A.

 (c) The permittee shall calculate and record the actual annual NOx and VOC emissions using appropriate emissions factors from U.S. EPA Publication AP-42 or appropriate alternative emission factors based on PADEP review, coupled with appropriate operational and thruput data.

 (d) The permittee shall maintain written documentation of the previously listed items in (a)—(c) for five years. The records shall be made available to the Department upon written request pursuant to 25 Pa. Code § 129.100(d) and (i).

 III. Sources 124 (Caster Vents), 132A (44" Mill Hot Rolling Operations), 132B (28"/35" Mill Hot Rolling Operations), 132C (20" Mill Hot Rolling Operations), 501B (Ladle Refining Furnace) and 922 (Compressed Air System Freeze Protection).

 (a) The permittee shall maintain and adhere to an operation and maintenance plan for Sources 124, 132A, 132B, 132C, 501B and 922, which shall address good operation and maintenance practices for the minimization of VOC emissions, and/or manufacturer's operating specifications.

 (b) The permittee shall maintain records of any maintenance or modifications performed on Sources 124, 132A, 132B, 132C, 501B and 922.

 (c) The permittee shall calculate and record the actual annual VOC emissions from Sources 124, 132A, 132B, 132C, 501B and 922 using appropriate emissions factors from U.S. EPA Publication AP-42 or appropriate alternative emission factors based on PADEP review, coupled with appropriate operational and thruput data.

 (d) The permittee shall maintain written documentation of the previously listed items in (a)—(c) for five years. The records shall be made available to the Department upon written request pursuant to 25 Pa. Code § 129.100(d) and (i).

Public Comment Details:

 Persons wishing to file a written protest or provide comments or additional information, which they believe should be considered prior to the issuance of a permit, may submit the information to Thomas Hanlon, Environmental Engineering Manager, Air Quality Permitting, at 909 Elmerton Avenue, Harrisburg, PA 17110. A 30-day comment period from the date of publication of this notice will exist for the submission of comments, protests and information. Each submission must contain the name, address and telephone number of the person submitting the comments, identification of the proposed RACT II Operating Permit including the permit number and a concise statement regarding the relevancy of the information or objections to issuance of the proposed RACT II Plan.

Public Hearing.

 A public hearing will be held on January 14, 2020, at 10:00 a.m. at the DEP Southcentral Regional Office, 909 Elmerton Avenue, Harrisburg, PA 17110, to accept oral comments on the proposed permit action and the proposed SIP revision. To register to speak at the hearing, please contact Thomas Hanlon at 717-705-4862. Speakers must pre-register in order to testify at the hearing. The last day to pre-register to speak at the hearing will be January 7, 2020.

 Oral testimony at the hearing will be limited to a maximum of 5 minutes per individual and two written copies of the oral testimony are requested. Each organization is requested to designate one witness to present testimony on its behalf. Persons unable to attend the hearing, may submit three (3) copies of a written statement and exhibits within 10 days thereafter to Thomas Hanlon at 909 Elmerton Avenue, Harrisburg, PA 17110.

 All pertinent documents are available for public review between 8 a.m. and 4 p.m. at the DEP Southcentral Regional Office at 909 Elmerton Avenue, Harrisburg, PA 17110. Appointments for scheduling a review may be made by calling Thomas Hanlon at 717-705-4862.

 Individuals who are in need of an accommodation for the hearing as provided for in the Americans with Disabilities Act should contact Thomas Hanlon at 717-705-4862 or make accommodations through the Pennsylvania AT&T Relay Service at 1-800-654-5984 (TDD).


Intent to Issue Operating Permits under the Air Pollution Control Act (35 P.S. §§ 4001—4015) and 25 Pa. Code Chapter 127, Subchapter F.

Southeast Region: Air Quality Program, 2 East Main Street, Norristown, PA 19401.

Contact: Janine Tullock-Reid, New Source Review Chief—Telephone: 610-832-6242.

15-00132: Teva Branded Pharmaceutical Products R&D Inc. (Teva) (145 Brandywine Parkway, West Chester, PA 19380) for a renewal of a State Only, Synthetic Minor Operating Permit in West Goshen Township, Chester County. Teva operates a pharmaceutical research and development facility with six (6) natural gas-fired boilers, five (5) diesel-fired emergency electric generators, three (3) natural gas-fired emergency electric generators, and miscellaneous gas-fired heaters. The pollutant of concern from this facility is nitrogen oxides (NOx). Teva shall continue to maintain a synthetic minor operating status by limiting its facility-wide nitrogen oxide (NOx) emissions to 24.9 tons per year, or less. Monitoring, record keeping and reporting requirements have been added to the permit to address applicable limitations.

09-00096: Suburban Heating Oil Partners (3115 State Hill Rd, Telford, PA 09869-1076) a renewal operating permit for operation of a fuel oil, gasoline and diesel fuel storage and loading facility in West Rockhill Township, Bucks County. The permit is for a non-Title V (State only) facility. The major sources of air emissions are: two (2) above ground gasoline storage tanks, two (2) kerosene above ground storage tanks, one (1) diesel underground storage tank, five (5) aboveground propane storage tanks, and a truck loading rack for: gasoline (with vapor balance controls), diesel, and kerosene. The permit will include monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

Northeast Region: Air Quality Program, 2 Public Square, Wilkes-Barre, PA 18711-0790.

Contact: Norman Frederick, Facility Permitting Chief—Telephone: 570-826-2409.

48-00038: Specialty Minerals, Inc. (640 N. 13th Street, Easton, PA 18042-1431). The Department intends to issue a renewal State-Only (Natural Minor) Permit for the commercial physical research services facility in Easton, Northampton County. The primary sources are boilers and machine shops. The control devices are baghouses. The sources are considered minor emission sources of nitrogen oxide (NOx), sulfur oxides (SOx), carbon monoxide (CO), total suspended particulate (TSP) and VOC's. The operating permit contains applicable requirements for emission limitations, work practice standards, testing, monitoring, recordkeeping, and reporting standards used to verify facility compliance with Federal and State air pollution regulations.

48-00109: Silbrico Corp. (4250 Braden Blvd., Forks Township, PA 18040). The Department intends to issue a new State-Only (Synthetic Minor) Permit for the non-metallic minerals processing facility in Easton, Northampton County. The primary sources are expansion furnaces, perlite mills, and material handling equipment. The control devices are baghouses and cyclones. The sources are considered minor emission sources of nitrogen oxide (NOx), sulfur oxides (SOx), carbon monoxide (CO), total suspended particulate (TSP) and VOC's. The operating permit contains applicable requirements for emission limitations, work practice standards, testing, monitoring, recordkeeping, and reporting standards used to verify facility compliance with Federal and State air pollution regulations.

40-00071: American Asphalt Paving Company (500 Chase Road Shavertown, PA 18708-9689). The Department intends to issue a renewal State-Only Synthetic Minor Permit for the American Asphalt Paving Co.—Chase Facility located in Jackson Township, Luzerne County. Business activities performed at this facility include non-metallic mineral mining and processing, and hot mix asphalt production. The sources are considered minor emission sources of nitrogen oxide (NOx), sulfur oxides (SOx), carbon monoxide (CO), total suspended particulate (TSP) and VOC's. The proposed permit contains applicable requirements for emission limitations, work practice standards, testing, monitoring, recordkeeping, and reporting standards used to verify facility compliance with Federal and State air pollution regulations.

54-00075: Yuengling Beer Co. Inc. (310 Mill Creek Avenue Pottsville, PA 17901-8692). The Department intends to issue a renewal State-Only Natural Minor Permit for their Mill Creek Brewery located in Jackson Township, Luzerne County. The sources are considered minor emission sources of nitrogen oxide (NOx), sulfur oxides (SOx), carbon monoxide (CO), total suspended particulate (TSP) and VOC's. The proposed permit contains applicable requirements for emission limitations, work practice standards, testing, monitoring, recordkeeping, and reporting standards used to verify facility compliance with Federal and State air pollution regulations.

Southcentral Region: Air Quality Program, 909 Elmerton Avenue, Harrisburg, PA 17110.

Contact: Thomas Hanlon, Facilities Permitting Chief, 717-705-4862, Thomas Bianca, New Source Review Chief, 717-705-4863, or William Weaver, Regional Air Quality Manager, 717-705-4702.

06-05087: Haines & Kibblehouse, Inc. (2052 Lucon Road, P.O. Box 196, Skippack, PA 19474) for their asphalt plant located at 1355 Reading Avenue, Bechtelsville, in Colebrookdale Township, Berks County. This is a renewal of the State Only Operating Permit issued in September 2014. The actual emissions from the facility in 2018 are estimated at 38.89 tons CO, 2.63 tons PM, 2.43 tons NOx and less than one ton of other pollutants. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations. Among other items, the conditions include provisions derived from 40 CFR 60 Subpart I (Standards of Performance for Hot Mix Asphalt Facilities).

67-03126: Yorkshire Animal Hospital (3434 East Market Street, York, PA 17402) to issue a State Only Operating Permit for the crematory located in Springettsbury Township, York County. The potential emissions are estimated at 1.87 tpy of NOx, 1.56 tpy of CO, 1.40 tpy of PM10, 0.63 tpy of SOx, and 0.14 tpy of VOC. The Operating Permit will include emission limits and work practice standards along with monitoring, recordkeeping and reporting requirements to ensure the facility complies with the applicable air quality regulations.

Southwest Region: Air Quality Program, 400 Waterfront Drive, Pittsburgh, PA 15222-4745.

Contact: Thomas Joseph, P.E., Facilities Permitting Chief—Telephone: 412-442-4336.

03-00263: Allegheny Mineral Corp.—Bison Mine (1 Glade Park Drive, Kittanning, PA 16201). Natural Minor State-Only Operating Permit is for a facility that crushes and processes limestone and is located in West Franklin Township, Armstrong County. In accordance with 25 Pa. Code §§ 127.424 and 127.425, the Department of Environmental Protection (DEP) has received an application and is providing notice that it intends to issue an Air Quality Operating Permit for the previously-mentioned facility. Sources of emissions consist of crushing and screening operations, a limestone wet washing system, stockpiles, truck loadout, and emissions from the use of roadways. Facility-wide potential emissions with controls are projected to be 36.0 TPY PM and 17.0 TPY PM-10. At a minimum, the facility is required to conduct daily surveys of the site to ensure compliance with visible, fugitive, and malodor emission requirements and maintain records of those surveys. The air quality permit includes operating requirements, monitoring requirements, and recordkeeping requirements for the site.

 Those who wish to provide the Department with additional written information that they believe should be considered prior to the issuance of the State-Only Operating Permit may submit the information to Tom Joseph, Facilities Permit Chief, Department of Environmental Protection, Southwest Regional Office, 400 Waterfront Drive, Pittsburgh, PA 15222. Written comments must contain the name, address and telephone number of the person submitting the comments, identification of the proposed Operating Permit (03-00263) and concise statements regarding the relevancy of the information or objections to issuance of the Operating Permit.

 A public hearing may be held, if the Department, in its discretion, decides that such a hearing is warranted based on the information received. All persons submitting comments or requesting a hearing will be notified of the decision to hold a hearing by publication in the newspaper or by the Pennsylvania Bulletin, or by telephone, where the Department determines such notification by telephone is sufficient. Written comments or requests for a public hearing should be directed to Tom Joseph, Facilities Permit Chief, at the previously listed address.

 All comments must be received prior to the close of business 30 days after the date of this publication.

 The application, DEP's Review Memorandum, and the proposed permit are available for public review during normal business hours at DEP's Southwest Regional Office, 400 Waterfront Drive, Pittsburgh, PA 15222. A file review can be scheduled through the DEP's website at https://www.dep.pa.gov/Citizens/PublicRecords/Pages/Informal-File-Review.aspx.

Northwest Region: Air Quality Program, 230 Chestnut Street, Meadville, PA 16335-3481.

Contact: Devendra Verma, New Source Review Chief—Telephone: 814-332-6940.

10-00230: Lindy Paving, Inc.'s Zelienople Plant (158 Lindsay Rd, Zelienople, PA 16063). The Department intends to issue the renewal of the State-Only Operating Permit of a hot mix asphalt (HMA) plant located in Jackson Township, Butler County. Permitted air contamination sources are a counter-flow drum mix asphalt plant, three asphalt cement storage tanks, four asphalt product storage silos, storage bins, material handling, material piles, and roadways. The current HMA plant was initially authorized through GP-13 issued in 2014. In this renewal, the current HMA plant is incorporated into the operating permit along with the GP-13 requirements, replacing the previously permitted HMA plant and all its plan approval-based requirements. The source test submittal procedure of GP-13 is revised in accordance with Source Testing Section's latest instructions. Under the authority of GP-13 Condition # 5, the facility elected to be subject to emission restrictions to limit its emissions below major source thresholds. Facility-wide restrictions of 99 TPY CO, 99 TPY NOx, 99 TPY PM10, and 49 TPY VOC apply to the facility to maintain its Synthetic Minor status.

24-00187: AgriPower Manufacturing and Services, Inc (230 State Street, St. Marys, PA 15857-1628). The Department of Environmental Protection intends to issue a State Only Operating Permit for a 9.35 MMBtu/hr biomass boiler at their physical research facility located in Saint Marys City, Elk County. The biomass boiler generates PM, SOx, NOx, CO, and VOC emissions. Filterable PM emissions are reduced by cyclonic capture. The facility is a natural minor facility. Potential emissions of PM, PM10, SOx, NOx, CO, CO, and VOC are 9.9 TPY, 9.0 TPY, 1,0 TPY, 12.2 TPY, 24.6 TPY, and 0.7 TPY, respectively. The permit contains emission restrictions, an operational restriction of 1,000 hours in any 12-month consecutive month period, recordkeeping, reporting, and work practice requirements designed to keep the facility operating within all applicable air quality requirements.

33-00151: Oak Heritage, Inc. (124 Industrial Park Dr, Brockway, PA 15824-1242). The Department is providing notice that they intend to renew a State Only Natural Minor Operating Permit for the custom, hand-crafted furniture manufacturing facility located in Brockway Borough, Jefferson County. The primary sources at the facility are the surface coating operations (spray booths and dip tanks). The potential emissions of the primary pollutants from the facility are as follows: 0.77 TPY (tons per year) NOx, 6.97 TPY CO, 20.11 TPY VOC, 4.64 TPY filterable PM-10 and PM-2.5, and 0.04 TPY SOx; thus, the facility is a natural minor. The surface coating operations are subject to 25 Pa. Code § 129.52 for surface coating processes. The renewal permit will contain emission restrictions, recordkeeping, work practices, and additional requirements to ensure compliance with the Clean Air Act and the Air Pollution Control Act.

Central Office: Air Quality, 400 Market Street, Harrisburg, PA 17101, 717.787.9702.

Department of Public Health, Air Management Services: 321 University Avenue, Philadelphia, PA 19104.

15-00132: Teva Branded Pharmaceutical Products R&D Inc. (Teva) (145 Brandywine Parkway, West Chester, PA 19380) for a renewal of a State Only, Synthetic Minor Operating Permit in West Goshen Township, Chester County. Teva operates a pharmaceutical research and development facility with six (6) natural gas-fired boilers, five (5) diesel-fired emergency electric generators, three (3) natural gas-fired emergency electric generators, and miscellaneous gas-fired heaters. The pollutant of concern from this facility is nitrogen oxides (NOx). Teva shall continue to maintain a synthetic minor operating status by limiting its facility-wide nitrogen oxide (NOx) emissions to 24.9 tons per year, or less. Monitoring, record keeping and reporting requirements have been added to the permit to address applicable limitations.

09-00096: Suburban Heating Oil Partners (3115 State Hill Rd, Telford, PA 09869-1076) for operation of a fuel oil, gasoline and diesel fuel storage and loading facility in West Rockhill Township, Bucks County. The permit is for a non-Title V (State only) facility. The major sources of air emissions are: two (2) above ground gasoline storage tanks, two (2) kerosene above ground storage tanks, one (1) diesel underground storage tank, five (5) aboveground propane storage tanks, and a truck loading rack for: gasoline (with vapor balance controls), diesel, and kerosene. The permit will include monitoring, recordkeeping and reporting requirements designed to keep the facility operating within all applicable air quality requirements.

COAL & NONCOAL MINING
ACTIVITY APPLICATIONS

 Applications under the Surface Mining Conservation and Reclamation Act (52 P.S. §§ 1396.1—1396.31); the Noncoal Surface Mining Conservation and Reclamation Act (52 P.S. §§ 3301—3326); the Clean Streams Law (35 P.S. §§ 691.1—691.1001); the Coal Refuse Disposal Control Act (52 P.S. §§ 30.51—30.66); the Bituminous Mine Subsidence and Land Conservation Act (52 P.S. §§ 1406.1—1406.21). Mining activity permits issued in response to such applications will also address the applicable permitting requirements of the following statutes: the Air Pollution Control Act (35 P.S. §§ 4001—4015); the Dam Safety and Encroachments Act (32 P.S. §§ 693.1—693.27); and the Solid Waste Management Act (35 P.S. §§ 6018.101—6018.1003).

 The following permit applications to conduct mining activities have been received by the Department of Environmental Protection. A copy of the application is available for inspection at the District Mining Office indicated above each application. Notices of requests for 401 Water Quality Certifications are included in individual application notices, as noted.

 Written comments or objections, or requests for an informal conference, or a public hearing, as applicable, on a mining permit application may be submitted by any person or any officer or head of any Federal, State or local government agency or authority to the Department at the address of the District Mining Office indicated above each application within 30-days of this publication, or within 30-days after the last publication of the applicant's newspaper advertisement, as provided by 25 Pa. Code §§ 77.121—77.123 and 86.31—86.34 (relating to public notices of filing of permit applications, opportunity for comment, and informal conferences).

 Written comments or objections related to a mining permit application should contain the name, address and telephone number of persons submitting comments or objections; application number; and a statement of sufficient detail to inform the Department on the basis of comment or objection and relevant facts upon which it is based.

 Requests for an informal conference, or a public hearing, as applicable, on a mining permit application, as provided by 25 Pa. Code § 77.123 (relating to public hearing-informal conferences) or § 86.34 (relating to informal conferences), must contain the name, address and telephone number of the requestor; the application number; a brief summary of the issues to be raised by the requestor at the conference; and a statement whether the requestor desires to have the conference conducted in the locality of the proposed mining activities.

 Where a National Pollutant Discharge Elimination System (NPDES) number is listed, the mining activity permit application was accompanied by an application for an individual NPDES permit. A separate notice will be provided after the draft NPDES permit is prepared.

Coal Applications Received

Effluent Limits—The following range of effluent limits will apply to NPDES permits issued in conjunction with the associated coal mining activity permit and, in some cases, noncoal mining permits:

Table 1

30-Day Daily Instantaneous
Parameter Average Maximum Maximum
Iron (total)    1.5 to 3.0 mg/l    3.0 to 6.0 mg/l    3.5 to 7.0 mg/l  
Manganese (total) 1.0 to 2.0 mg/l 2.0 to 4.0 mg/l 2.5 to 5.0 mg/l
Suspended solids 10 to 35 mg/l 20 to 70 mg/l 25 to 90 mg/l
Aluminum (Total) 0.75 to 2.0 mg/l 1.5 to 4.0 mg/l 2.0 to 5.0 mg/l
pH1 greater than 6.0; less than 9.0
Alkalinity greater than acidity1
1 The parameter is applicable at all times.

 A settleable solids instantaneous maximum limit of 0.5 ml/l applied to: surface runoff (resulting from a precipitation event of less than or equal to a 10-year 24-hour event) from active mining areas; active areas disturbed by coal refuse disposal activities; and mined areas backfilled and revegetated; and drainage (resulting from a precipitation event of less than or equal to a 1-year 24-hour event) from coal refuse disposal piles.

Coal Applications Received

Moshannon District Mining Office: 186 Enterprise Drive, Philipsburg, PA 16866, 814-342-8200, (Contact: Janet Turner).

17110109 and NPDES PA0257818. King Coal Sales, Inc., P.O. Box 712, Philipsburg, PA 16866, permit renewal for continued operation and restoration of a bituminous surface coal mine located in Morris Township, Clearfield County affecting 85.7 acres. Receiving stream(s): Unnamed Tributary to Hawk Run classified for the following use(s): CWF. There are no potable water supply intakes within 10 miles downstream. Application received: December 4, 2019.

17090103 and NPDES PA0257079. Bell Resources, Inc., 1340 Hoyt Road, Curwensville, PA 16833, permit renewal for continued operation and restoration of a bituminous surface coal mine located in Boggs and Knox Townships, Clearfield County affecting 311.9 acres. Receiving stream(s): Unnamed Tributaries No. 1 and No. 2 to Clearfield Creek classified for the following use(s): CWF. There are no potable water supply intakes within 10 miles downstream. Application received: December 6, 2019.

New Stanton District Office: P.O. Box 133, 131 Broadview Road, New Stanton, PA 15672, 724-925-5500. (Contact: Tracy Norbert).

63130102. Amerikohl Mining, Inc. (1384 State Route 711, Stahlstown, PA 15687), renewal application for continued mining of an existing bituminous surface mine located in Nottingham Township, Washington County, affecting 65.9 acres. Receiving stream(s): unnamed tributaries to Sugar Run and unnamed tributaries to Mingo Creek classified for the following use(s): HQ-TSF. There is no potable water supply intake within 10 miles downstream from the point of discharge. Application received: December 11, 2019.

Pottsville District Mining Office: 5 West Laurel Boulevard, Pottsville, PA 17901, 570-621-3118, (Contact: Theresa Reilly-Flannery).

Permit No. 40850201R7. Atlantic Carbon Group, Inc. (P.O. Box 39, Hazleton, PA 18201), renewal of an existing anthracite coal refuse reprocessing operation in Hazle Township, Luzerne County affecting 108.7 acres. Receiving stream: unnamed tributary to Catawissa Creek and Catawissa Creek, classified for the following uses: cold water and migratory fishes. Application received: December 4, 2019.

Noncoal Applications Received

Effluent Limits—The following effluent limits will apply to NPDES permits issued in conjunction with a noncoal mining permit:

Table 2

30-day Daily Instantaneous
Parameter Average Maximum Maximum
Suspended solids    10 to 35 mg/l    20 to 70 mg/l    25 to 90 mg/l  
Alkalinity exceeding acidity*
pH* greater than 6.0; less than 9.0
* The parameter is applicable at all times.

 A settleable solids instantaneous maximum limit of 0.5 ml/l applied to surface runoff resulting from a precipitation event of less than or equal to a 10-year 24-hour event. If coal will be extracted incidental to the extraction of noncoal minerals, at a minimum, the technology-based effluent limitations identified under coal applications will apply to discharges of wastewater to streams.

Knox District Mining Office: P.O. Box 669, 310 Best Avenue, Knox, PA 16232-0669, 814-797-1191, (Cayleigh Boniger).

22807-37160303-E-2. Amerikohl Aggregates, Inc. (202 Sunset Drive, Butler, PA 16001). Application for a stream encroachment to construct support facility and maintenance within 100 feet but no closer than 10 feet of an unnamed tributary to the Beaver River, Wayne Township, Lawrence County. Receiving streams: Unnamed tributaries to Connoquenessing Creek, Connoquenessing Creek, and unnamed tributaries to the Beaver River, classified for the following uses: WWF. The first downstream potable water supply intake from the point of discharge is Beaver Falls Municipal Water Authority. Application received: October 25, 2019.

New Stanton District Office: P.O. Box 133, 131 Broadview Road, New Stanton, PA 15672, 724-925-5500. (Contact: Tracy Norbert).

02910301 (formerly 3474SM46) and NPDES Permit No. PA0589853. Collier Stone Co., 80 Noblestown Road, Carnegie, PA 15106, NPDES renewal received for continued mining of an existing noncoal surface mine in Collier Township, Allegheny County, affecting 34.5 acres. Receiving stream(s): Robinson Run and Scotts Run classified for the following use(s): WWF. Application received: November 25, 2019.

Pottsville District Mining Office: 5 West Laurel Boulevard, Pottsville, PA 17901, 570-621-3118, (Contact: Theresa Reilly-Flannery).

Permit No. 66090301C and NPDES Permit No. PA0225274. Noxen Sand & Materials (2162 Chase Road, Shavertown, PA 18708), renewal of an NPDES Permit for discharge of treated mine drainage from a quarry operation in Noxen Township, Wyoming County affecting 24.6 acres. Receiving stream: Beaver Run, classified for the following use: HQ—cold water fishes. Application received: November 22, 2019.

MINING ACTIVITY NPDES DRAFT PERMITS

 This notice provides information about applications for a new, amended or renewed NPDES permits associated with mining activity (coal or noncoal) permits. The applications concern industrial waste (mining) discharges to surface water and discharges of stormwater associated with mining activities. This notice is provided in accordance with 25 Pa. Code Chapters 91 and 92a and 40 CFR Part 122, implementing provisions of The Clean Streams Law (35 P.S. §§ 691.1—691.1001) and the Federal Clean Water Act (33 U.S.C.A. §§ 1251—1376).

 The Department of Environmental Protection (Department) has prepared a draft NPDES permit and made a tentative determination to issue the NPDES permit in conjunction with the associated mining activity permit.

Effluent Limits for Coal Mining Activities

 For coal mining activities, NPDES permits, when issued, will contain effluent limits that are the more stringent of technology-based (BAT) effluent limitations or Water Quality Based Effluent Limits (WQBEL).

 The BAT limits for coal mining activities, as provided in 40 CFR Part 434 and 25 Pa. Code Chapters 87—90 are as follows:

30-Day Daily Instantaneous
Parameter Average Maximum Maximum
Iron (Total) 3.0 mg/l 6.0 mg/l 7.0 mg/l
Manganese (Total) 2.0 mg/l 4.0 mg/l 5.0 mg/l
Suspended solids 35 mg/l 70 mg/l 90 mg/l
pH* greater than 6.0; less than 9.0
Alkalinity greater than acidity*
*The parameter is applicable at all times.

 A settleable solids instantaneous maximum limit of 0.5 ml/l applies to: surface runoff (resulting from a precipitation event of less than or equal to a 10-year 24-hour event) from active mining areas; active areas disturbed by coal refuse disposal activities; mined areas backfilled and revegetated; and all other discharges and drainage (resulting from a precipitation event of greater than 1-year 24-hour to less than or equal to a 10-year 24-hour event) from coal refuse disposal piles. Similarly, modified BAT limits apply to iron, manganese and suspended solids in surface runoff, discharges and drainage resulting from these precipitation events and those of greater magnitude in accordance with 25 Pa. Code §§ 87.102, 88.92, 88.187, 88.292, 89.52 and 90.102.

 Exceptions to BAT effluent limits may be applicable in accordance with 25 Pa. Code §§ 87.102, 88.92, 88.187, 88.292, 89.52 and 90.102.

Effluent Limits for Noncoal Mining Activities

 The limits for noncoal mining activities as provided in 25 Pa. Code Chapter 77 are pH 6 to 9 and other parameters the Department may require.

 Discharges from noncoal mines located in some geologic settings (for example, in the coal fields) may require additional water quality based effluent limits. If additional effluent limits are needed for an NPDES permit associated with a noncoal mining permit, then the permit description specifies the parameters.

 In addition to BAT or WQBEL limits, coal and noncoal NPDES permits establish effluent limitations in the form of implemented Best Management Practices (BMPs) identified in the associated Erosion and Sedimentation Plan, the Reclamation Plan and the NPDES permit application. These BMPs restrict the rates and quantities of associated pollutants from being discharged into surface waters in this Commonwealth.

 More restrictive effluent limitations, restrictions on discharge volume or restrictions on the extent of mining that may occur are incorporated into an NPDES permit when necessary for compliance with water quality standards and antidegradation requirements (in accordance with 25 Pa. Code Chapters 91—96).

 The procedures for determining the final effluent limits, using a mass-balance equation or model, are found in Technical Guidance Document 563-2112-115, Developing National Pollutant Discharge Elimination System (NPDES) Permits for Mining Activities. Other specific factors to be considered include public comments and Total Maximum Daily Load(s). Additional discharge limitations may apply in the event that unexpected discharges occur.

 Discharge rates for surface mining activities are precipitation driven. Discharge rates for proposed discharges associated with underground mining are noted in the permit description.

 Persons wishing to comment on an NPDES draft permit should submit a written statement to the Department at the address of the district mining office indicated before each draft permit within 30-days of this public notice. Comments received within the comment period will be considered in the final determinations regarding the NPDES permit applications. Comments must include the name, address and telephone number of the writer and a concise statement to inform the Department of the exact basis of a comment and the relevant facts upon which it is based.

 The Department will also accept requests or petitions for a public hearing on NPDES permit applications, as provided in 25 Pa. Code § 92a.82(d). The request or petition for a public hearing shall be filed within 30-days of this public notice and contain the name, address, telephone number and the interest of the party filing the request and state the reasons why a hearing is warranted. A public hearing may be held if the Department considers the public interest significant. If a hearing is scheduled, a notice of the hearing on the NPDES permit application will be published in the Pennsylvania Bulletin and a newspaper of general circulation within the relevant geographical area. When a public hearing is held, the Department will consider comments from the public hearing in the final determination on the NPDES permit application.

Coal NPDES Draft Permits

New Stanton District Office: P.O. Box 133, 131 Broadview Road, New Stanton, PA 15672, 724-925-5500. (Contact: Tracy Norbert).

NPDES No. PA0252255, (Mining Permit No. 63120104), Neiswonger Construction, Inc., 17592 Route 322, Strattanville, PA 16258. Renewal of an NPDES permit for a bituminous surface mine located in Deemston Borough, Washington County. Receiving streams: UNT to Fishpot Run and Fishpot Run, classified for the following use: WWF. Draft NPDES permit effluent limits are as follows. Application received: November 19, 2018.

 The following mine drainage treatment outfall discharges to Fishpot Run:

Outfall No. New Outfall (Y/N) Type
TP3 N MDT

 The proposed effluent limits for the previously listed outfall are as follows:

Outfall: TP3 30-Day Daily Instant.
Parameter Average Maximum Maximum
Total Iron (mg/l) 3.0 6.0 7.0
Total Manganese (mg/l) 2.0 4.0 5.0
Total Aluminum (mg/l) 2.0 4.0 5.0
Total Suspended Solids (mg/l) 35 70 90
Total Sulfates (mg/L) Monitor and Report
Flow (gpm) Monitor and Report
Temperature (°C) Monitor and Report
Specific Conductivity (µmhos/cm) Monitor and Report
pH (S.U.): Must be between 6.0 and 9.0 standard units at all times.
Alkalinity must exceed acidity at all times.

 The following stormwater outfall discharges to UNT to Fishpot Run:

Outfall Nos. New Outfall (Y/N) Type
SP5 N SWO

 The proposed effluent limits for the previously listed outfall are as follows:

Outfalls: SP5 30-Day Daily Instant.
Parameter Average Maximum Maximum
Total Iron (mg/l) 1.5 3.0 3.7
Total Manganese (mg/l) 1.0 2.0 2.5
Total Aluminum (mg/l) 0.75 0.75 0.75
Total Suspended Solids (mg/l) 35 70 90
Total Sulfates (mg/l) Monitor and Report
Osmotic Pressure (mOsm/kg) Monitor and Report
Flow (gpm) Monitor and Report
Temperature (°C) Monitor and Report
Specific Conductivity (µmhos/cm) Monitor and Report
pH (S.U.): Must be between 6.0 and 9.0 standard units at all times.
Alkalinity must exceed acidity at all times.

Noncoal NPDES Draft Permits

Knox District Mining Office: P.O. Box 669, 310 Best Avenue, Knox, PA 16232-0669, 814-797-1191, (Cayleigh Boniger).

NPDES No. PA0227781 (Permit No. 24980102). Tamburlin Brothers Coal Company, Inc. (P.O. Box 1419, Clearfield, PA 16830). Renewal of an NPDES permit for a bituminous surface mine in Fox Township, Elk County, affecting 196.0 acres. Receiving streams: Limestone Run to Little Toby Creek, classified for the following uses: CWF. TMDL: Little Toby Creek. Application received: September 24, 2019.

 Unless otherwise noted for a specific outfall, the proposed effluent limits for all outfalls in this permit are the BAT limits described previously for coal mining activities.

 The following outfalls discharge to Limestone Run:

Outfall No. New Outfall (Y/N)
001 N
002 N
003 N
004 N

 The proposed effluent limits for the previously listed outfalls are as follows:

30-Day Daily Instant.
Parameter Minimum Average Maximum Maximum
pH1 (S.U.) 6.0 9.0
Alkalinity greater than acidity1
Iron (mg/l) 3.0 6.0 7.0
Manganese (mg/l) 2.0 4.0 5.0
Aluminum (mg/l) 0.75 0.75 0.75
Total Suspended Solids (mg/l) 35.0 70.0 90.0
1 The parameter is applicable at all times.

FEDERAL WATER POLLUTION
CONTROL ACT, SECTION 401

 The following permit applications, requests for Environmental Assessment approval and requests for 401 Water Quality Certification have been received by the Department of Environmental Protection. Section 401 of the Federal Water Pollution Control Act (FWPCA) (33 U.S.C.A. § 1341), requires the State to certify that the involved projects will not violate the applicable provisions of Sections 301—303, 306 and 307 of the FWPCA 33 U.S.C.A. §§ 1311—1313, 1316 and 1317, as well as relevant State requirements. Persons objecting to approval of a request for certification under Section 401 or to the issuance of a Dam Permit or Water Obstruction and Encroachment Permit, or the approval of an Environmental Assessment must submit any comments, suggestions or objections within 30-days of the date of this notice, as well as any questions to the office noted above the application. Comments should contain the name, address and telephone number of the person commenting, identification of the certification request to which the comments or objections are addressed, and a concise statement of comments, objections or suggestions including the relevant facts upon which they are based.

 The Department may conduct a fact-finding hearing or an informal conference in response to comments if deemed necessary. Each individual will be notified, in writing, of the time and place of a scheduled hearing or conference concerning the certification request to which the comment, objection or suggestion relates. Maps, drawings and other data pertinent to the certification request are available for inspection between the hours of 8:00 AM and 4:00 PM on each working day at the office noted above the application.

 If you are a person with a disability and wish to attend the hearing and you require an auxiliary aid, service or other accommodation to participate in the proceedings, please contact the specified program. TDD users may contact the Department through the Pennsylvania AT&T Relay Service at (800) 654-5984.

WATER OBSTRUCTIONS AND ENCROACHMENTS


Applications Received Under the Dam Safety and Encroachments Act (32 P.S. §§ 693.1—693.27) and Section 302 of the Flood Plain Management Act (32 P.S. § 679.302) and Requests for Certification Under Section 401 of the Federal Water Pollution Control Act (33 U.S.C.A. § 1341(a)).

Southcentral Region: Waterways & Wetlands Program, 909 Elmerton Avenue, Harrisburg, PA 17110.

Contact: Edward Muzic, Section Chief, 717.705.4802.

E3803219-002. J.D. Oliver, 4360 Lewis Road, P.O. Box 4714, Harrisburg, PA 17111 in Union Township, Lebanon County, ACOE Baltimore District.

 To 1.) place and maintain fill in two palustrine emergent wetlands and the floodway of an unnamed tributary to Swatara Creek, impacting 0.07 acre of wetland and 0.05 acre of floodway, for the purpose of constructing a commercial truck repair facility. The project is located near the intersection of S.R. 934 and Old Forge Road (Latitude: 40° 26` 56.73" N; Longitude: 76° 30` 48.09" W) in Union Township, Lebanon County. To compensate for the wetland impacts, J.D. Oliver will purchase 0.07 acre of wetland credits from the Codorus Creek mitigation bank in York County, Pennsylvania.

E6703219-010. PPL Electric Utilities Corporation, Two North Ninth Street, Allentown, PA 18104-8342, Fairview Township, York County, ACOE Baltimore District.

 To construct and maintain a temporary causeway, temporarily impacting 275 feet of Yellow Breeches Creek (CWF, MF) (Latitude: 40.2259°N; Longitude: 76.8595°W).

 The proposed project impacts in this permit application are associated with an upgrade of an electric transmission pipeline project extending across the Susquehanna in New Cumberland Borough, Cumberland County, Fairview Township, York County, Steelton Borough and Swatara Township Dauphin County. No wetland loss is proposed with this project and replacement is not required.

E2203219-008: PPL Electric Utilities Corporation, Two North Ninth Street, Allentown, PA 18104-8342, Steelton Borough and Swatara Township, Dauphin County, ACOE Baltimore District.

 To construct and maintain 1.) an electric transmission line across the Susquehanna River, permanently impacting 3,655 feet of the River; 2.) a temporary causeway in the Susquehanna River (WWF, MF), temporarily impacting 2,425 feet of the River; and 3.) a temporary wetland crossing, impacting 0.15 acre of wetland (Latitude: 40.2264°N, Longitude 76.8591°W).

 The proposed project impacts in this permit application are associated with an upgrade of an electric transmission pipeline project extending across the Susquehanna in New Cumberland Borough, Cumberland County, Fairview Township, York County, Steelton Borough and Swatara Township Dauphin County. No wetland loss is proposed with this project and replacement is not required.

E2103219-005. PPL Electric Utilities Corporation, Two North Ninth Street, Allentown, PA 18104-8342, New Cumberland Borough, Cumberland County, ACOE Baltimore District.

 To construct and maintain 1.) a temporary causeway, temporarily impacting 275 feet of Yellow Breeches Creek (CWF, MF) and 550 feet of its floodway; and 2.) two monopoles impacting 20 square feet of the floodway of Yellow Breeches Creek (CWF, MF) (Latitude: 40.2259°N; Longitude: 76.8595°W).

 The proposed project impacts in this permit application are associated with an upgrade of an electric transmission pipeline project extending across the Susquehanna in New Cumberland Borough, Cumberland County, Fairview Township, York County, Steelton Borough and Swatara Township Dauphin County. No wetland loss is proposed with this project and replacement is not required.

Southeast Region: Waterways and Wetlands Program, 2 East Main Street, Norristown, PA 19401, Telephone 484.250.5160.

Contact: Gladys Jean Schlosser, Clerical Supervisor 2, 484.250.5028.

Permit No. E09-1040, New Britain Township, 207 Park Avenue, Chalfont, PA 18914, New Britain Township, Bucks County, ACOE Philadelphia District.

 To perform the following listed water obstruction and encroachment activities associated with the Peace Valley Nature Center. The proposed project consists of the construction of a 30,746 square foot pervious parking lot and 39-foot diameter Pavilion. The construction of the parking lot and Pavilion will have limited temporary floodplain impacts (North Branch Neshaminy Creek, WWF, MF).