Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Code website reflects the Pennsylvania Code changes effective through 53 Pa.B. 8238 (December 30, 2023).

Pennsylvania Code



CHAPTER 15. GRANDSTANDS

GENERAL PROVISIONS

Sec.


15.1.    Definitions.
15.2.    Scope.
15.3.    Classes.
15.4.    Responsibility of owners.
15.5.    Penalty.

RULES OF CONSTRUCTION


15.11.    Applicability.
15.12.    Plans for permanent grandstands.
15.13.    Approval.
15.14.    Design and workmanship.
15.15.    Loading.
15.16.    Foundations.
15.17.    Materials.
15.18.    Allowable stresses.
15.19.    Special requirements.
15.20.    Painting and treatment of members.
15.21.    Existing construction.

Authority

   The provisions of this Chapter 15 issued under act of April 27, 1927 (P. L. 465, No. 299) (35 P. S. § §  1221—1235.1), unless otherwise noted.

Source

   The provisions of this Chapter 15 adopted August 15, 1933; amended through July 1, 1968, unless otherwise noted.

GENERAL PROVISIONS


§ 15.1. Definitions.

 The following words and terms, when used in this chapter, have the following meanings, unless the context clearly indicates otherwise:

   Foldable grandstand—An assembly of prefabricated units used to produce a grandstand which may be readily folded, rolled or telescoped into a small space when not in use, and easily extended for use as support for audiences.

   Grandstand—A structure, including bleachers, intended primarily to support persons attending athletic events, parades, concerts or other types of assembly, including permanent seating in theatres, churches, auditoriums and similar buildings.

   Permanent grandstand—A grandstand, other than a portable or foldable grandstand, permanently erected upon and attached to concrete or masonry footings.

   Portable grandstand—An assembly of prefabricated units able to be readily erected, dismantled and transported on base plates, sills, floor runners or sleepers.

   Steel grandstand—A grandstand, the majority of whose main structural members, such as columns, struts, beams, stringers and the like, are constructed of iron or steel.

   Wood grandstand—A grandstand, the majority of whose main structural members, such as columns, struts, beams, stringers and the like, are constructed of wood.

Source

   The provisions of this §  15.1 adopted August 15, 1933; amended through July 1, 1968.

§ 15.2. Scope.

 This chapter pertains to grandstands in which the main structural members consist of steel or wood. A grandstand of a design or material not covered by this chapter shall be of an approved type, and subject to the loading requirements of §  15.15 (relating to loading) and other requirements the Department may determine.

Source

   The provisions of this §  15.2 adopted August 15, 1933; amended through July 1, 1968.

§ 15.3. Classes.

 Grandstands covered by this chapter are divided into two general classes: new construction and existing construction.

Source

   The provisions of this §  15.3 adopted August 15, 1933; amended through July 1, 1968.

§ 15.4. Responsibility of owners.

 Owners shall be responsible for the maintenance of grandstands in their original condition unless permission to make changes is obtained from the Department.

Source

   The provisions of this §  15.4 adopted August 15, 1933; amended through July 1, 1968.

§ 15.5. Penalty.

 A person who violates a provision of this chapter or a regulation of the Department or who interferes with the Department or its authorized representatives in the enforcement of the provisions or regulations shall upon conviction be punishable under section 13 of the act of April 27, 1927 (P. L. 465, No. 299) (35 P. S. §  1233).

Source

   The provisions of this §  15.5 adopted August 15, 1933; amended through July 1, 1968.

RULES OF CONSTRUCTION


§ 15.11. Applicability.

 This section and § §  15.12—15.21 apply equally to portable, foldable and permanent grandstands, except where the context clearly indicates otherwise.

Source

   The provisions of this §  15.11 adopted August 15, 1933; amended through July 1, 1968.

§ 15.12. Plans for permanent grandstands.

 (a)  Under section 8 of the act of April 27, 1927 (35 P. S. §  1228), detailed plans for the new construction or remodeling of permanent grandstands shall be submitted to the Department in triplicate for approval before building operations are begun.

 (b)  The plans shall show the details of construction, including the size and material of the members, and the method of anchorage. The applicant shall submit his calculations of design for the structural members. Specifications shall also be furnished if requested.

 (c)  A fee of $75 will be charged for the examination of plans for permanent grandstands. The payment shall be made by check or money order, payable to the Commonwealth, at the time of submission of the plans.

Source

   The provisions of this §  15.12 adopted August 15, 1933; amended through July 1, 1968; amended January 12, 1990, effective January 13, 1990, 20 Pa.B. 183. Immediately preceding text appears at serial page (8339).

Cross References

   This section cited in 34 Pa. Code §  15.11 (relating to applicability).

§ 15.13. Approval.

 (a)  A petition shall be made to the Secretary to secure approval of portable and foldable grandstands. The petition shall be accompanied by photographs or cuts and complete plans and design calculations of the members and connections submitted in triplicate.

 (b)  An applicant shall include calculations for live, dead, sway and wind loads for all structural members of portable, foldable and permanent grandstands.

 (c)  Detailed plans and design calculations of permanent grandstands shall be submitted for approval before building operations begin. The grandstands shall be inspected after erection and permission granted by the Department before they may be used.

Source

   The provisions of this §  15.13 adopted August 15, 1933; amended through July 1, 1968.

Cross References

   This section cited in 34 Pa. Code §  15.11 (relating to applicability).

§ 15.14. Design and workmanship.

 (a)  The design of grandstands shall conform to the best modern engineering practice; the design or method of construction shall be in accordance with established principles of mechanics. Prior to granting approval of portable and foldable grandstands, the Department may require that tests be performed under the supervision of a nationally recognized testing laboratory in the presence of a representative of the Department. The test shall be performed upon a full-size, complete structural unit of the grandstand, having the maximum number of rows on which approval is desired. The grandstand being tested shall be loaded, vertically and horizonally, with not less than 1 1/2 times the loads prescribed in §  15.17 (relating to materials). After removal of the loads, no member of the grandstand may show permanent deformation, nor may the connections or bolt holes show permanent deformity.

 (b)  Workmanship shall be of such quality as to produce in construction the full strength intended by the designer.

 (c)  A portable grandstand shall be self-contained, including parts necessary to withstand and restrain forces which may develop during human occupancy. The strength, stability or safety of the structure may not depend upon stakes, curbs, walls or other external objects. A foldable grandstand, if permanently attached to the wall of a building, may depend upon the wall for resistance to horizontal loads, but not for the support of vertical loads.

 (d)  A grandstand may not be occupied until all parts have been securely assembled in accordance with the approved design and specifications.

 (e)  Grandstands shall be so designed that the maximum expansion, contraction, settlement or misalignment which may occur during the life of the grandstand will not cause stresses in excess of those specified, nor jeopardize the strength or stability of the structure or the safety of its occupants. The owner shall provide and maintain proper bearing surface for outdoor installations.

 (f)  The owner of a building in which grandstands are to be used shall provide walls and floors of sufficient strength to withstand the loads and stresses caused by the grandstand when loaded, as specified in §  15.17.

Source

   The provisions of this §  15.14 adopted August 15, 1933; amended through July 1, 1968.

Cross References

   This section cited in 34 Pa. Code §  15.11 (relating to applicability).

§ 15.15. Loading.

 (a)  Seats and foot rests of grandstands shall be designed to support, in addition to their own weight, a uniformly distributed live load of 120 pounds per linear foot of seatboard and footrest. Other parts of grandstands shall be designed to support, in addition to their own weight, a uniformly distributed live and impact load according to the back to back distance between seats as follows:

Back to Back of Seats
(in inches)
Pounds per Square Foot
22130
23125
24120
25115
26110
27105
More than 27100

 (b)  Grandstands shall be designed to resist, when occupied, a horizontal swaying force applied to the seats, in a direction parallel to the length of the seats of 24 pounds per linear foot of seats, and in a direction perpendicular to the length of the seats of ten pounds per linear foot of seats. On grandstands supporting chairs these loads shall be applied at a height of 17 inches above the foot rest.

 (c)  Grandstands able to be used outdoors shall be designed to resist a horizontal wind load on the vertical projection of the stand, applied in any direction, as follows:

   (1)  When fully loaded, 4 pounds per square foot.

   (2)  When unoccupied, if of open construction, 15 pounds per square foot.

   (3)  When unoccupied, if filled in solid vertically, 30 pounds per square foot.

   (4)  Vertical projection shall include railings.

 (d)  Members whose stresses are greater under a partial loading of the stand than under full load, shall be designed to meet the conditions causing the largest stresses.

 (e)  The design shall remain stable so as not to be overturned by wind or unequal distribution of the live load.

Source

   The provisions of this §  15.15 adopted August 15, 1933; amended through July 1, 1968.

Cross References

   This section cited 34 Pa. Code §  15.11 (relating to applicability).

§ 15.16. Foundations.

 (a)  Permanent grandstands for outdoor use shall be erected upon and attached to concrete or masonry footings extending below the surface of the ground to a depth of either 3 feet or the maximum depth of frost, whichever is greater, unless solid rock is encountered at a lesser depth.

 (b)  Portable grandstands shall be provided by the manufacturers with base plates and sills, floor runners or sleepers of such area that the total live and dead load does not exceed 14 pounds per square inch of the base plate, mud sills, floor runners or sleepers. The owner shall see that all bearing surfaces are in contact.

 (c)  Base plates, mud sills or another part of the structure in contact with the earth may be subject to no stresses other than those caused by the vertical forces resulting from live, dead, sway and wind loads and the horizontal friction resulting from sway and wind loads. The stress shall be limited to those set forth in §  15.20 (relating to painting and treatment of members) reduced as follows:

   (1)  For base members of pressure-treated wood, allowable stresses shall be reduced by 1/4.

   (2)  For base runners of ungalvanized steel, allowable stresses shall be reduced by 2/3.

   (3)  For base members of galvanized steel, no reduction in allowable stress is required.

 (d)  In the absence of definite knowledge of the sustaining power of the earth, different soils, excluding mud and artificial fill, shall be deemed to sustain safely the following loads per square inch:

Material
Pounds per Square Inch
Soft clay 14
Wet sand, firm clay or sand and clay mixed 28
Fine and dry sand 42
Hard, dry clay or coarse sand 50
Gravel 55
Hard pan110
Soft, firm rock140
Medium rock200
Hard rock400

 (e)  For grandstands on artificial fill, either the sustaining power of the earth shall be determined by test, or the foundations shall be extended down to the natural earth, whose sustaining power shall be computed from the loads per square inch set forth in subsection (d).

Source

   The provisions of this §  15.16 adopted August 15, 1933; amended through July 1, 1968.

Cross References

   This section cited in 34 Pa. Code §  15.11 (relating to applicability).

§ 15.17. Materials.

 (a)  Steel. Wherever used, steel shall conform to the standard specifications of the American Institute of Steel Construction, as amended. In addition, load carrying steel members of permanent grandstands for outdoor use, and of portable grandstands, including steel members which may be in contact with the earth may not be less than 1/4 inch thick, except for the following:

   (1)  The web of rolled structural shapes may be not less than 17/100 inch thick.

   (2)  The deck plates of a steel-deck grandstand, railings and hot galvanized load carrying members not in contact with the earth, may not be less than 3/16 inch thick.

   (3)  In foldable and permanent grandstands used entirely indoors the required thickness of steel may be decreased 50%, if in all other respects it complies with the requirements of this chapter, and if the location and usage of a member is such that there is no likelihood of distortion which might affect the safety of the grandstand.

 (b)  Wood. Each wood structural member shall be well seasoned and of a quality not less than the lowest grade in the respective species, as provided in §  15.18(b) (relating to allowable stresses). The quality of seats may be not less than the lowest grade of finish lumber, and of boarding and sheathing not lower than No. 2 common grade. In specifying wooden parts, the species and grade and the actual finished sizes of the parts shall be given.

 (c)  Other materials. Other materials, where used, shall be suitable, of uniform quality, and without defects affecting the strength or service of the grandstand.

Source

   The provisions of this §  15.17 adopted August 15, 1933; amended through July 1, 1968.

Cross References

   This section cited in 34 Pa. Code §  15.11 (relating to applicability); and 34 Pa. Code §  15.14 (relating to design and workmanship).

§ 15.18. Allowable stresses.

 (a)  For steel. Parts of the structure shall be so proportioned that the sum of the maximum stresses in pounds per square inch does not exceed the following:

   (1)  Tension. Tension shall be regulated as follows:

ItemMaximum Stresses
(pounds per square inch)
Structural steel, net section20,000
Butt welds, section through throat20,000
Rivets on area based on nominal diameter20,000
Bolts and other threaded parts, on nominal area at root of thread20,000

   (2)  Compression. Compression shall be regulated as follows:

     (i)   For the purposes of this paragraph, symbols represent the following:

       L = The unsupported length of the column.

       r = The corresponding least radius of gyration of the section.

     (ii)   Rolled steel, on short length or where lateral deflection is prevented, may not exceed 20,000 pounds per square inch.

     (iii)   On a gross section of columns, L/r does not exceed 120:

       1,700 - .485 L2 /r2

   if L/r exceeds 120:

       1 + [(18,000 ÷ L2) ÷ 18,000r2 ]

     (iv)   The ratio of unbraced length to least radius of gyration L/r for compression members and for tension members other than rods shall not exceed the following:

Item
Maximum Stresses
(pounds per square inch)
For main compression members120
For bracing and other secondary members in compression200
For main tension members240
For bracing and other secondary members in tension300

   (3)  Bending. Bending shall be regulated as follows:

     (i)   For the purposes of this paragraph, the following designations will apply:

       L = The unsupported length of the column.

       b = The width of the compression flange.

     (ii)   Extreme fibres of rolled shapes, and built up sections, net section, if lateral deflection is prevented, may not exceed 20,000 pounds per square inch.

     (iii)   Where L exceeds 15 times b, the stress in pounds per square inch in b may not exceed the following:

       1 + [(20,000 ÷ L2 ) ÷ 2,000b2 ]

     (iv)   The laterally unsupported length of beams and girders may not exceed 40 times b in width of the compression flange.

     (v)   Extreme fibres of pins, when the forces are assumed as acting at the center of gravity of the pieces may not exceed 30,000 pounds per square inch.

   (4)  Shearing. Shearing shall be regulated as follows:

     (i)   For the purposes of this paragraph, the following designations will apply:

       A = The gross area of the web in inches.

       V = The total shear.

       h = The height between flanges in inches.

       t = The thickness of the web in inches.

     (ii)   The following table will apply:

ItemMaximum Stresses
(pounds per square inch)
Pins15,000
Power-driven rivets15,000
Turned bolts in reamed holes with a clearance of not more than 1/50 inch15,000
Hand-driven rivets10,000
Unfinished bolts10,000
The gross area of the webs of beams and girders where h is not more than 60 times t13,000

     (iii)   The gross area of the webs of beams and girders if the web is not stiffened, where h is more than 60 times t, the thickness of the web, the maximum shear per square inch, V/A may not exceed:

       1 + [(18,000 ÷ h2 ) ÷ 7,200t2 ]

     (iv)   A section through the throat of a fillet weld may not exceed 13,600 pounds per square inch.

   (5)  Bearing. Bearing shall be regulated as follows:

     (i)   For the purposes of this paragraph, the letter ‘‘d’’ shall designate the diameter of the roller in inches.

     (ii)   The following table will apply:

Maximum Stresses
(pounds per square inch)
Item Single Shear
Double Shear
Pins32,000
32,000
Power-driven rivets32,000
40,000
Turned bolts in reamed holes32,000
40,000
Hand-driven bolts20,000
25,000
Unfinished bolts20,000
25,000

     (iii)   On expansion rollers, pounds per linear inch, -600d.

   (6)  Combined stresses. Combined stresses shall conform with the following:

     (i)   For the purposes of this paragraph, the following designations will apply:

       Fa = Axial unit stress that would be permitted by this specification if axial stress only existed.

       Fb = Bending unit stress that would be permitted by this specification if bending stress only existed.

       fa = Axial unit stress (actual) = axial stress divided by area of member.

       fb = Bending unit stress (actual) = bending moment divided by section modulus of member.

     (ii)   For stresses due to wind sway loads, combined with those due to dead or live loads, the permissible total working stress may be increased 33 1/3%, if the section thus found is not less than that required by the dead or live loads alone.

     (iii)   Members subject to both axial and bending stresses shall be so proportioned that the quantity fa/Fa+fb/Fb does not exceed unity.

   (7)  Members carrying wind and sway only. For members carrying wind and sway stresses only, the permissible working stresses may be increased 33 1/3%.

   (8)  Welding. Welds shall be made only by operators who have qualified by the tests prescribed in the Standard Qualification Procedure of the American Welding Society to perform the type of work required, except that this provision need not apply to tack welds not later incorporated into finished welds carrying calculated stress.

 (b)  For wood. Allowable unit stresses for wood parts of grandstands shall be considered in light of the following:

   (1)  Wood parts shall be so designed and proportioned that their stresses do not exceed the allowable unit stresses in the following table:

Allowable Unit Stresses in Pounds Per Square Inch for Wood parts of Grandstands Based on the American Lumber Standards

   (2)  A species or grade of wood excluded from paragraph (1) may not be used except when permitted by the Department and after the wood is determined to be satisfactory.

   (3)  For stresses produced by wind loads or impact only, or by a combination of wind or impact loads and dead and live loads, allowable stresses may be increased 50% if the resulting sections are not less than those for dead and live loads alone.

   (4)  Connections to wooden members shall be by means of rivets, bolts, lag screws, except lag screws in tension or for field connections or approved modern timber connectors. It is recommended that a bulletin issued in the United States Department of Commerce entitled, ‘‘Modern Connection for Timber Construction’’ be consulted. The use of nails and wood screws is permissible for holding parts together, but for designing purposes the nails or screws shall be considered incapable of transmitting calculable stresses.

   (5)  Nails or screws may not be used if their loosening or splitting of the surrounding wood causes stresses in excess of those permitted or would jeopardize the strength and stability of the structure or the safety of its occupants.

   (6)  Connections to wooden tension members may be by means of not less than two bolts, rivets or lag screws or approved modern timber connectors. Reference should be made to the bulletin referred to in paragraph (4). Adequate provision shall be made to prevent wood splitting at such connections.

   (7)  The bearing values of bolts in wood shall be calculated by the following tables:

     (i)   Basic stresses for calculating safe loads for bolted joints shall be subject to the following:

Basic Stress
(pounds per square inch)
GroupSpecies of Wood Parallel with
the Grain
Perpendicular
to the Grain
Softwoods (conifers)
2Cedar, Alaska, Port Oxford and western red1,000200
2Douglas fir (Rocky Mountain region)1,000200
2Hemlock, western1,000200
2Pine, Norway1,000200
3Cypress, southern1,300275
3Douglas fir (coast region)1,300275
3Larch, western1,300275
3Pine, southern yellow1,300275
3Redwood1,300275
3Tamarack1,300275
Hardwoods (broad-leaved species)
2Maple (soft), red and silver1,200250
2Elm, American and slippery1,200250
2Gum, black, red, and tupelo1,200250
2Sycamore1,200250
3Ash, commercial white1,500400
3Beech1,500400
3Birch, sweet and yellow1,500400
3Elm, rock1,500400
3Hickory, true and pecan1,500400
3Maple (hard), black and sugar1,500400
3Oak, commercial red and white1,500400

       (A)   The stresses set forth in subparagraph (i) apply to seasoned timber used in dry covered locations. Exposed parts of grandstands which may be used outdoors require 7/8 of those values.

       (B)   When the stress is neither parallel nor perpendicular to the grain of the wood, the maximum basic stress in pounds per square inch shall not exceed the following:

Equation to Title 34—§ 15.18

       in which P is the allowable basic stress parallel with the grain, Q is the allowable basic stress perpendicular to the grain, and O is the angle between the direction of the grain and the direction of the load normal to the face considered.

     (ii)   The percentages of basic stress parallel with the grain for calculating safe bearing stresses under bolts shall be derived as follows:

Length of
Bolt in
Main
Percentage of Basic Stress for—
Member
Divided
Common BoltsHigh-strength Bolts
by its
Diameter
Group 1Group 2Group 3Group 1Group 2Group 3
(L/D) WoodsWoodsWoodsWoodsWoodsWoods
1.0100.0100.0100.0100.0100.0100.0
1.5100.0100.0100.0100.0100.0100.0
2.0100.0100.0100.0100.0100.0100.0
2.5100.0100.097.7100.0100.0100.0
3.0100.0100.099.0100.0100.0100.0
3.5100.099.396.7100.0100.099.7
4.099.597.492.5100.0100.099.0
4.597.993.886.8100.0100.097.8
5.095.488.380.0100.099.896.0
5.591.482.273.0100.098.293.0
6.085.675.867.2100.095.489.5
6.579.070.062.098.592.285.2
7.073.465.057.695.888.881.0
7.568.560.653.792.785.076.8
8.064.256.950.489.381.273.0
8.560.453.547.485.977.769.6
9.057.150.644.882.574.266.4
9.554.147.942.479.071.063.2
10.051.445.540.375.868.060.2
10.548.943.338.472.564.857.4
11.046.741.436.669.761.954.8
11.544.739.635.066.859.252.4
12.042.837.933.664.056.750.2
12.541.136.432.261.454.448.2
13.039.535.031.059.152.446.3

       (A)   The product of the basic stress parallel with the grain selected from the table set forth in paragraph (7)(i), and the percentage for the particular L/D ratio and species group taken from the table set forth in subparagraph (i), is the safe working stress at that ratio for joints with metal splice plates. If wood splice plates are used, each of which is 1/2 the thickness of the main timber, 80% of this product is the safe working stress.

       (B)   The common bolts referred to in subparagraph (i) are those having a yield point of approximately 45,000 pounds per square inch.

       (C)   The high-strength bolts referred to in subparagraph (i) are those having a yield point of approximately 125,000 pounds per square inch.

     (iii)   The percentages of basic stress perpendicular to the grain used in calculating safe bearing stresses under bolts shall be derived as shown in the following tables:

TABLE I


Percentage for Common Bolts
Length of
Bolt in
Main
Member
divided by its
Diameter
(L/D)
Group 1
Conifers
and
Group 1
Hardwoods
Group 2
Conifers
Group 2
Hardwoods
and
Group 3
Conifers
Group 3
Hardwoods
Percentage
for High-
Strength
Bolts
(all groups)
1.0100.0100.0100.0100.0100.0
5.5100.0100.0100.099.0100.0
6.0100.0100.0100.096.3100.0
6.5100.0100.099.592.3100.0
7.0100.0100.097.386.9100.0
7.5100.099.193.381.2100.0
8.0100.096.188.175.0100.0
8.598.191.782.169.999.8
9.094.686.376.764.697.7
9.590.080.971.960.094.2
10.085.076.267.255.490.0
10.580.171.662.951.685.7
11.076.167.659.348.481.5
11.572.164.155.645.477.4
12.068.661.052.042.573.6
12.565.358.049.040.070.2
13.062.255.345.937.566.9



TABLE II


Diameter of Bolt
(in inches)
Diameter Factor
1/42.50
3/81.95
1/21.68
5/81.52
3/41.41
7/81.33
11.27
1-1/41.19
1-1/21.14
1-3/41.10
21.07
2-1/21.03
3 and over1.00


       (A)   The safe working stress for a given value of L/D is the product of three factors:

         (I)   The basic stress perpendicular to the grain taken from the table in paragraph (7)(i).

         (II)   The percentage from the table set forth in clause (A).

         (III)   The factor for bolt diameter, as set forth in clause (B).

       (B)   No reduction need be made when wood splice plates are used except that the safe load perpendicular to the grain should never exceed the safe load parallel to the grain for any given size and quality of bolt and timber.

       (C)   The common bolts referred to in Table I are those having a yield point of approximately 45,000 pounds per square inch.

       (D)   The high-strength bolts referred to in Table I are those having a yield point of approximately 125,000 pounds per square inch.

   (8)  For other materials. Other materials when used shall be so designed and proportioned that their stresses do not exceed the allowable unit stresses generally accepted as safe by engineering practice.

Source

   The provisions of this §  15.18 adopted August 15, 1933; amended through July 1, 1968.

Cross References

   This section cited in 34 Pa. Code §  15.11 (relating to applicability); and 34 Pa. Code §  15.17 (relating to materials).

§ 15.19. Special requirements.

 (a)  Railings shall be provided along the back of the grandstands if the rear seat is more than 4 feet above the ground, along those portions of the ends when the seats are more than 4 feet above the ground, and along the front if the front footrest is more than 1 foot, 6 inches above the ground. Railings along the rear and ends may be not less than 3 feet high above center of the nearest seat. When railings are required along the front, they may be not less than 3 feet high above the front footrest. The maximum dimension of a clear vertical opening in a railing may not be greater than 18 inches. This subsection shall be complied with by a mid-rail, wire fabric or other suitable means. Railings shall be capable of safely sustaining a vertical load of 80 pounds per linear foot and a horizontal thrust of 25 pounds per linear foot. When grandstands are used adjacent to a wall or fence, railings may be omitted from those portions where the wall or fence affords equivalent protection, if the gap between seat or foot rest and wall or fence does not exceed 6 inches. When the topmost seat of a stand is greater than 15 feet above the ground, the maximum dimension of a clear vertical opening between the rails of the back rail may not be greater than 12 inches.

 (b)  A grandstand having a railing along the front shall be provided with aisles so located that no portion of a seat is more than 25 feet, 6 inches from the nearest aisle. A grandstand having seats with backs shall be provided with aisles, so located that no portion of a seat is more than 18 feet from the nearest aisle. Aisles so provided may be not less than 3 feet wide, except that where an aisle is divided into two parts, one on each side of a portal, column or other obstruction, each part may be 2 feet wide. When the entrance to an aisle is elevated above the ground level, each aisle shall be provided with a stairway or ramp, whose width is not less than the width of the aisle. An aisle may not be immediately adjacent to the end of a portable or foldable grandstand. Stairs shall have a maximum slope of 10 degrees. Ramps shall have nonslip surfaces. Where aisles are provided adjacent to the end of permanent grandstands, the width of the aisles shall be a minimum of 2 feet wide.

 (c)  Footrests shall preferably be located above the stringer to avoid tripping. The width of footrests in permanent grandstands shall be the full open space between two rows of seats. The width of footrests in portable grandstands is preferably the full open width between seats. In no case may the width be less than 9 1/2 inches. The width of seats may also be not less than 9 1/2 inches.

 (d)  Seats shall be securely fastened to their supports in such a manner that they cannot accidentally be displaced. Footrests shall be so supported that they are not accidentally displaced a sufficient distance to endanger the occupant of the grandstand. Footrests which are lapped shall be provided with some positive means to prevent displacement of one piece on the other.

 (e)  The horizontal distance back to back of seats may not be less than 22 inches. When the same level is used for both seats and footrests the levels may not be less than 22 inches in width.

Source

   The provisions of this §  15.19 adopted August 15, 1933; amended through July 1, 1968.

Cross References

   This section cited in 34 Pa. Code §  15.11 (relating to applicability).

§ 15.20. Painting and treatment of members.

 (a)  Steel. Steelwork may be either painted or galvanized by the hot-dip process. If galvanized, it shall be thoroughly cleaned and the minimum thickness or weight of zinc applied shall be .0034 inch, or 2 ounces per square foot of surfaces (1 ounce of zinc per square foot of surface corresponds to a coating thickness of .0017 inch). The galvanized coating shall be capable of withstanding a six dip Preece Test. If painted, it shall be thoroughly cleaned and given not less than one coat of rust inhibiting paint of the best quality.

 (b)  Wood. Wood in contact with the earth shall be pressure treated with creosote or an equal preservative. Other wood shall be either pressure treated or given not less than one coat of good protecting paint, varnish, lacquer or an equivalent finish, either before or not more than 2 weeks after erection.

Source

   The provisions of this §  15.20 adopted August 15, 1933; amended through July 1, 1968.

Cross References

   This section cited in 34 Pa. Code §  15.11 (relating to applicability); and 34 Pa. Code §  15.16 (relating to foundations).

§ 15.21. Existing construction.

 (a)  Existing permanent and portable grandstands may continue to be used if determined to be safe by the Department.

 (b)  A grandstand determined by the Department to be unsafe for occupancy may not again be used unless made safe according to the instructions of the Department.

Source

   The provisions of this §  15.21 adopted August 15, 1933; amended through July 1, 1968.

Cross References

   This section cited in 34 Pa. Code §  15.11 (relating to applicability).



No part of the information on this site may be reproduced for profit or sold for profit.


This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.