Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Code website reflects the Pennsylvania Code changes effective through 54 Pa.B. 488 (January 27, 2024).

34 Pa. Code § 43.72. Locks.

§ 43.72. Locks.

 (a)  Each bulkhead in tunnels of 12 feet or more in diameter (or equivalent area) shall have at least two locks in perfect working condition, one of which shall be used as a man-lock.

 (b)  The man-lock shall be large enough so that those using it are not compelled to be in a cramped position, and it shall not be less than 5 feet in height. The emergency lock shall be large enough to hold an entire heading shift.

 (c)  All locks used for decompression shall be lighted by electricity and shall contain a pressure gauge, a time piece, a glass ‘‘bull’s eye’’ in each door or in each end, and shall also have facilities for heating.

 (d)  Valves shall be arranged so that the locks may be operated both within and without.



No part of the information on this site may be reproduced for profit or sold for profit.


This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.