34 Pa. Code § 23.103. Flues.

§ 23.103. Flues.

 (a)  All flues and discharge outlets of vent apertures shall be provided with suitable wire screen or equivalent to avoid hazards to surrounding properties.

 (b)  Flues and discharge pipes shall extend at least 6 feet above the roof lines or ceiling level of the drycleaning or dyeing room and shall not terminate within 10 feet, measured horizontally, of any door, window or frame wall of any adjoining or adjacent building.