Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Code website reflects the Pennsylvania Code changes effective through 54 Pa.B. 1032 (February 24, 2024).

34 Pa. Code § 7.99. Sheaves and drums of hoisting chains and cables.

§ 7.99. Sheaves and drums of hoisting chains and cables.

 (a)  When chains or cables are used for raising or lowering the cars of new power-operated sidewalk elevators, the sheaves or winding drums shall not be less than ten inches in diameter. The sheaves or winding drums of hand-operated sidewalk elevators shall be at least 10 inches in diameter when cables are used, but when chains are used a lesser diameter is permitted, if the sheaves are pocketed to receive the chains. Cable sizes shall be at least 3/8 inch in diameter. Sheaves or winding drums shall be equipped with substantial retaining flanges.

 (b)  Power-driven sidewalk elevators suspended from cables or chains shall be provided with approved rope-type car safeties. Such safeties shall be capable of stopping or holding the fully-loaded elevator car at any point of its travel.



No part of the information on this site may be reproduced for profit or sold for profit.


This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.