Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Code website reflects the Pennsylvania Code changes effective through 54 Pa.B. 1032 (February 24, 2024).

34 Pa. Code § 47.261. Post fastenings.

RAILINGS FOR NEW INSTALLATIONS


§ 47.261. Post fastenings.

 Pipe posts shall be fastened to the floor or structual frame by pipe flanges secured by rivets, tap bolts, or through-bolts with plates or washers in the case of steel construction or through-bolts with plates or washers in the case of wood construction. When fastened to wood, the bolts shall be so arranged that no two bolt holes are in line with the grain of the wood. Each flange shall be secured by not less than four rivets or bolts of sufficient diameter to insure a permanent rigid anchorage. Other approved methods of securing pipe flanges to concrete floors may be used. Reference should be made to Plate 1-C, D, E and Plate 4 of the Appendix.

Cross References

   This section cited in 34 Pa. Code §  47.281 (relating to post fastenings).



No part of the information on this site may be reproduced for profit or sold for profit.


This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.